SerialGate User Guide
65
Menu
Default
Descriptions
Once a UDP packet is received to the socket that waits for the
connection, the data is transmitted to the serial port. The data input
from the serial port is put into UDP packets, which eventually are
sent to the client.
UDP Client
When the data is input to the serial port, UDP packets are sent using
the preset IP address and the socket number of the server.
Pair_Master/ Pair_Slave
It extends a serial cable between DTE and DCE to network, and
enables communication not limited to distance. Two devices are
required for this feature and set one to Pair_master and another to
Pair_Slave. It can be used for serial communication tunneling.
MODBUS ASCII
Connect MODBUS/ASCII SLAVE using serial port and make user of
MODBUS/TCP MASTER feature using LAN port in PC. This feature
enables MODBUS media converter function. (Available for SG-
1010/ALL).
User Application
A user can run own customized program. In order to run it, a user
needs to ask for application development environment to
SystemBase.
Interface
RS232,
RS422
RS485
RS232 model is set to RS-232.
Combo model is selectable between RS-422, RS-485(No-Echo) and
RS-485(Echo). Default value is RS-422.
All model is selectable between RS-232, RS-422, RS-485(No-Echo)
and RS-485(Echo). Default value is RS-232.
SG-1160/ALL model is selectable between RS-232, RS-422, RS-
485(No-Echo) and RS-485(Echo). Default value is RS-232 and
termination can be configured.
Local
Socket Port
4001
Set the socket number for the port. TCP server and UDP server
operation mode makes use of this port for awaiting network socket
connections.
Port Alias
Port1
Name each port for convenience. 16 Characters at maximum.