SerialGate User Guide
49
Menu
Default
Descriptions
(Only applies to TCP Client, TCP Server, TCP Broadcast, and TCP
Multiplex operation modes.)
Latency
Time
0
This needs to be set when consecutive data from the given serial
port needs to be transmitted to socket at once.
For example, if 100 bytes of character string are to be transmitted
from the serial device to a server through SerialGate, bypass is set to
0 for the latency time. Although it provides immediate sending
through SerialGate, the server could be received a lot parts of
divided packets.
If the latency time is not 0, SerialGate will wait for the time and check
new data. If there is new data, SerialGate repeatedly wait for the
time. Otherwise, SerialGate will transfer the buffered data, but it
could not run in real time.
Trigger
Level
TX
Auto
If data is empty below the setting value in serial port’s output buffer, it
sends data to output buffer.
(Option: Auto, 1,2,4,8,16,32,64,96,128)
In Auto setting, it controls depending on the set communication
speed.
Trigger
Level
Rx
Auto
If there is more data over the setting value in serial port’s input buffer,
it reads data from input buffer.
(Option: Auto, 1,2,4,8,16,32,64,96,128)
In Auto setting, it controls depending on the set communication
FIFO Size 128
Linked to Trigger Level Tx, it sets the FIFO size that outputs data
(Option: 1 ~ 128)
Port Login Disable
When the Operation Mode is set to TCP Server, ask for the
username and password when the client tries to connect
(Options: Enable, Disable)
Passive
Username
serialgate
When the Operation Mode is set to TCP Server, set the username to
ask for. 16 Characters at maximum.
Passive
Password
99999999
When the Operation Mode is set as TCP Server, set the password to
ask for. 16 Characters at maximum.