RECOMMENDATIONS FOR INSTALLATION

FAN COIL INSTALLATION

Before installing the appliance, ensure that:

1) the place of installation has suffi cient space for carrying out installation as 

well as routine and extraordinary maintenance work (see Pic. 4).

2) There are no obstructions for air intake and delivery.

3) The water connections are of the sizes, in the position and spaced apart as 

required by the appliance (see Dimension).

4) The system pressure does not exceed 8 bar for the water versions.

5) The electricity supply corresponds to the data on the appliance rating plate 

and that there is a afety switch readily accessible to the user to cut off the power 

supply whenever necessary.

6) The safety switch is in the OFF position so that there is no voltage on the 

appliance supply line. 

Before installing the appliance, remove the housing (if present). Raise the fl aps 

covering the control panel and the water connections. Remove the two screws 

fi xing the housing to the fan coil load-bearing structure. Gipping the rear of the 

housing, remove it as shown in the Pic. 5 (NOTE: be careful of the lugs on the 

front part of the load-bearing structure, as shown in Pic.10).

Put the cabinet in the packing box  to prevent it from being soiled or damaged 

(Pic.6)

Offer the appliance up to the required point of installation and mark, through the 

fi xing holes, the points on the wall where the holes should be driller for the 4 

screw anchors, as shown in Pic. 7. 

To replace the housing.

Take the cabinet from the packing box. Standing in front of the fancoil, lift cabi-

net, holding it by the sides, and tilt it (Pic. 10).

Insert the lugs A into the relative slots B (Pic.11). Pivot the cabinet on its base 

until it is aligned with the wall. Raise the fl aps covering the control panel and 

water connections and tighten the two fi xing screws (Pic.5).

Remove the appliance from the point of installation, drill the holes where mer-

ked on the wall (see Pic. 8) and insert the screw anchors. Place the appliance 

against the wall and fi x it by tightening the screws into the anchors see (Pic. 

9). Carry out the water and electrical connections as described in the relevant 

paragraphs.

Pic. 04

lato attacchi
idraulici

Pic. 10

Pic. 11

Pic. 06

Pic. 07

Pic. 05

Pic. 08

Pic. 09

A

B

>150

>90

>140

Содержание SYSCOIL MINI 21

Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL LOW PROFILE CENTRIFUGAL FAN COIL UNIT SYSCOIL MINI 2012 0...

Страница 2: ......

Страница 3: ...COMMENDATIONS FOR INSTALLATION 6 FAN COIL INSTALLATION 6 WATER CONNECTIONS 7 Connection to the water mains 7 Condensate water drainage 7 ELECTRICAL CONNECTIONS 7 CONNECTION TO THE TERMINAL BLOCK 7 Wit...

Страница 4: ...he appliance works by electricity at mains voltage 230 Vac 50 Hz Always bear in mind that mains voltage is potentially dangerous and any appliance connected to it should be used with caution Before ca...

Страница 5: ...ng slots 9 Coil fixing screws 10 Load bearing structure 2 10 3 4 7 6 6 5 1 9 8 7 GENERAL TECHNICAL DATA MODEL 21 22 23 24 25 Power supply 230V 1 50Hz Tab 1 226 350 68 105 56 220 180 C D M L 110 350 22...

Страница 6: ...coil load bearing structure Gipping the rear of the housing remove it as shown in the Pic 5 NOTE be careful of the lugs on the front part of the load bearing structure as shown in Pic 10 Put the cabi...

Страница 7: ...ding not only the working current required by the appliance but also the necessary current for powering household and other electrical appliances already in use Any electrical and mechanical alteratio...

Страница 8: ...nt or the terminal block fixing it to the side opposite the water fittings the motor and sensor cables 3 if present fixing them with their grips Ensure that the cables pass through the hole in the sid...

Страница 9: ...ersion is the same USING THE CONTROL PANEL If the appliance has a built in control panel raise the flap and proceed as follows Heating mode Put the season selector switch from the off position to the...

Страница 10: ...ge position on the control panel Possible cause water in the system not hot enought Possible remedy check that the outlet temperature is above 40 C Little outflowing air Possible cause clogged filter...

Страница 11: ...NOTES...

Страница 12: ...With the perspective of improvement and against the continuous action of research and development the Manufacturer might modify even without any prior notice the given technical data systemair com...

Отзывы: