INTRODUCTION

RECOMMENDATIONS

This installation, operation and maintenance booklet should always accompany 

the fancoil ready consultation by the installer or user if necessary. The appliance 

should be installed in compliance with regulations in force in each country and 

according to the manufacturer’s or qualifi ed installer’ instruction. The manufac-

turer cannot be held liable for any damage to property or injury to persons and 

animals caused by incorrect installation of the appliance. Only qualifi ed persons 

should install the appliance and connect it to the mains electricity supply. Before 

carrying out any work on the appliance, ensure that it disconnected from the 

electricity supply. Read this instruction booklet before installing the appliance.

The appliance is easy to use, ut it is important to read this guide completely 

before using for the fi rst time.

This will help you:

- use the appliance in all safety;

- obtain best performance;

- avoid errors;

- respect the environment.

- Do not allow children or unassisted handicapped persons to use the 

                    

appliance.

- Do not touch the appliance with wet parts of the body or if barefoot.

- Do not tug, pull or twist electrical cables attached to the appliance, even when 

disconnected from the electricity supply.

- Do not open the fl aps giving access to the internal parts of the appliance wi-

thout having fi rst put the system on-off switch to “off”.

- Do not introduce sharp pointed objects through the air intake and outlet gril-

les.

- Do not leave packing material (cardboard, staples, plastic bags, etc.) within 

reach of children since they could be a source of danger.

- Dispose of correctly.

- Do not sit or climb on the appliance or rest any type of object on it.

- Do not spray or throw water directly on the appliance.

- Do not use the appliance in places with suspended dust/powder or in poten-

tially explosive atmospheres, in very damp environments or in  

the  pre-

sence of oil in suspension or in particularly aggressive atmospheres.

- Do not cover the appliance with objects or drapes that even partially obstruct 

the air fl ow.

- The appliance works by electricity at mains voltage (230 Vac, 50 Hz). Always 

bear in mind that mains voltage is potentially dangerous and any appliance 

connected to it should be used with caution. Before carrying out any work on the 

appliance, disconnect it from the electricity supply (by pulling out the plug from 

the mains socket or isolating the supply line by putting the on-off switch to off).

- If the appliance is not to be used for long periods, make sure that the controls 

are in the position 0 (off). If the appliance is not going to be used in winter when 

temperatures are near to freezing, drain the system and ensure that the applian-

ce heat exchanger has no water in it in order to prevent the formation of ice and 

consequent breakage. 

- To make the appliance inoperable, disconnect it totally from the electricity sup-

ply.

- It is unsafe to alter or try to alter the characteristics of this product. Any tampe-

ring or alteration renders the warranty null and void.

- In the event of malfunction or failure, do not try to repair the appliance yourself; 

contact a qualifi ed technician. Repairs carried out by unqualifi ed persons could 

cause damage or accidents.

- Always keep the appliance clean. In particular clean the air fi lter  periodically 

(at least once a month).

FAILURE TO COMPLY WITH THE ASSEMBLY INSTRUCTIONS GIVEN IN 

THIS GUIDE RELIEVES THE MANUFACTURER OF ALL AND ANY LIABILI-

TY. INCORRECT INSTALLATION COULD CAUSE MALFUNCTIONING OR 

FAILURE OF THE APPLIANCE. COULD ALSO REPRESENT A HAZARD 

FOR THE USER.

TRASPORTATION, RECEIVING, HANDLING

The appliance  is dispatched enclosed in special protective packaging, which 

should be kept intact until the appliance is positioned in the fi nal place of in-

stallation.

The appliance should be handled with extreme care, always keeping it in its 

original packaging.

To take the appliance out of the packaging, proceed as Pic. 1:

1. Turn the fan coil box upside down and open the bottom.

2. Remove the polystyrene fi lling and keep it.

3. Keeping the bottom of the box open, turn the pack 180°, taking care that 

the contents are fi rmly hald before resting it  gently on the ground. Lift off the 

packaging from the appliance.

SAFETY RULES

Secure packs during transportation.

Do not expose to the elements.

Do not tread on packs.

Protect hands with work gloves when dismantling the appliance.

Work in PAIRS if the applinance weighs more than 25 kg.

Содержание SYSCOIL MINI 21

Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL LOW PROFILE CENTRIFUGAL FAN COIL UNIT SYSCOIL MINI 2012 0...

Страница 2: ......

Страница 3: ...COMMENDATIONS FOR INSTALLATION 6 FAN COIL INSTALLATION 6 WATER CONNECTIONS 7 Connection to the water mains 7 Condensate water drainage 7 ELECTRICAL CONNECTIONS 7 CONNECTION TO THE TERMINAL BLOCK 7 Wit...

Страница 4: ...he appliance works by electricity at mains voltage 230 Vac 50 Hz Always bear in mind that mains voltage is potentially dangerous and any appliance connected to it should be used with caution Before ca...

Страница 5: ...ng slots 9 Coil fixing screws 10 Load bearing structure 2 10 3 4 7 6 6 5 1 9 8 7 GENERAL TECHNICAL DATA MODEL 21 22 23 24 25 Power supply 230V 1 50Hz Tab 1 226 350 68 105 56 220 180 C D M L 110 350 22...

Страница 6: ...coil load bearing structure Gipping the rear of the housing remove it as shown in the Pic 5 NOTE be careful of the lugs on the front part of the load bearing structure as shown in Pic 10 Put the cabi...

Страница 7: ...ding not only the working current required by the appliance but also the necessary current for powering household and other electrical appliances already in use Any electrical and mechanical alteratio...

Страница 8: ...nt or the terminal block fixing it to the side opposite the water fittings the motor and sensor cables 3 if present fixing them with their grips Ensure that the cables pass through the hole in the sid...

Страница 9: ...ersion is the same USING THE CONTROL PANEL If the appliance has a built in control panel raise the flap and proceed as follows Heating mode Put the season selector switch from the off position to the...

Страница 10: ...ge position on the control panel Possible cause water in the system not hot enought Possible remedy check that the outlet temperature is above 40 C Little outflowing air Possible cause clogged filter...

Страница 11: ...NOTES...

Страница 12: ...With the perspective of improvement and against the continuous action of research and development the Manufacturer might modify even without any prior notice the given technical data systemair com...

Отзывы: