background image

1 Declaration of Conformity

Manufacturer

Systemair UAB
Linų st. 101
LT-20174 Ukmergė, Lithuania
Office: +370 340 60165 Fax: +370 340 60166
www.systemair.com

hereby confirms that the following products:

DVCompact DXR–10

DVCompact DXR–15

DVCompact DXR–20

DVCompact DXR–25

DVCompact DXR–30

DVCompact DXR–40

DVCompact DXR–50

DVCompact DXR–60

DVCompact DXR–80

(The declaration applies only to product in the condition it was delivered in and installed in the facility in
accordance with the included installation instructions. The insurance does not cover components that are
added or actions carried out subsequently on the product)

Comply with all applicable requirements in the following directives

Machinery Directive 2006/42/EC

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

Ecodesign Directive 2009/125/EC

The following regulations are applied in applicable parts:

327/2011

Requirements for fans

1253/2014

Requirements for ventilation units

The following harmonized standards are applied in applicable parts:

EN ISO 12100:2010

Safety of machinery – General principles for design – Risk assessment and risk
reduction.

EN 13857

Safety of machinery – Safety distances to prevent hazard zones being reached by
upper or lower limbs

EN 60 335-1

Household and similar electrical appliances – Safety Part 1: General requirements

EN 60 335-2-80

Household and similar electrical appliances – Safety – Part 2-80: Particular
requirements for fans.

EN 62233

Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure.

EN 50 106:2007

Safety of household and similar appliances – Particular rules for routine tests referring
to appliances under the scope of EN 60 335-1 and EN 60967

EN 60 529

Degrees of protection provided by enclosures (IP Code)

EN 60 204-1

Safety of machinery – Electrical equipment of machines – Part 1: General requirements

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for
industrial environments

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission
standards for residential, commercial and light-industrial environments

The complete technical documentation is available.

Skinnskatteberg, 03-05-2016

Mats Sándor
Technical Director

DVCompact

Installation and Service

211117

1

Systemair Sverige AB

Содержание DVCompact DXR-10

Страница 1: ...atalogues brochures and other printed material UAB Systemair reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can b...

Страница 2: ...Unloading on the site 7 6 1 1 Unloading by fork lift truck 7 6 1 2 Unloading with crane 8 6 1 3 Lifting the unit mounted on a base frame 8 7 Installation 9 7 1 Unpacking 9 7 2 Where to Install the Un...

Страница 3: ...principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60 335 1 Household and similar...

Страница 4: ...splace the air and cause asphyxiation in unfavorable conditions Caution For safety reasons only personnel with relevant technical competence may perform installation work The installation instructions...

Страница 5: ...d or recovered during maintenance servicing and final disposal will need to be recorded along with leak checks actions taken the name of the service Company the engineer technician who performed the s...

Страница 6: ...and product number from the type label figure 1 Fig 1 Type label Position Description 1 Product order number 2 Product code product specification 3 Product item number production number consecutive n...

Страница 7: ...3510 1720 1720 1497 DVCompact DXR 50 970 2320 4310 2020 2020 2516 DVCompact DXR 60 1120 2320 4610 2170 2170 3309 DVCompact DXR 80 1270 24601 5050 2470 2470 3664 1 This section is split into 3 parts di...

Страница 8: ...PM Motor A DVCompact DXR 10 2 2 2 4 2 2 1 DVCompact DXR 15 3 0 3 4 2 6 2 9 DVCompact DXR 20 4 4 4 7 3 6 3 8 DVCompact DXR 25 4 4 6 0 4 7 6 4 4 6 6 3 DVCompact DXR 30 6 0 8 0 6 4 8 2 6 2 8 4 DVCompact...

Страница 9: ...emoved and unit covered with tarpaulin or similar materials In order to minimize condensation sufficient air circulation must be ensured between the covering and the unit During transportation the uni...

Страница 10: ...on 6 1 3 Lifting the unit mounted on a base frame When lifting the unit mounted on the base frame with holes use metal tubes inserted through the holes in the frame and suspend the unit by soft cables...

Страница 11: ...ng should if possible be put in the northern or eastern side of the building and away from other exhaust outlets like kitchen fan outcasts or laundry room outlets The extract air should ideally be led...

Страница 12: ...m size 50 don t have the disc lock system Their sections are fitted together by the use of internal triangular brackets that are fitted from factory figure figure 5 Danger Make sure that the Mains sup...

Страница 13: ...t figure 4 See wiring diagram for more information Other temperature sensors are built in to the unit from factory Fig 4 Installed supply air sensor 7 4 2 Installation of VAV models If the unit is del...

Страница 14: ...ped with traps with same diameter as the drain pipe Fig 6 Drain trap Positive pressure Positive pressure Pa H1 Min mm H2 mm 500 90 65 750 120 90 1000 150 120 Fig 7 Drain trap Negative pressure Negativ...

Страница 15: ...wn cable 7 Connection to black cable 7 5 Electrical connections Danger All electrical connections must be carried out in accordance with local rules and regulations Make sure that the power supply to...

Страница 16: ...s A and heat pump section pos B The unit must not be put into operation before all the electrical safety precautions have been read and understood See the enclosed wiring diagram for internal and exte...

Страница 17: ...51 52 53 LON 57 58 59 RS 485 contact and Exo line via TCP IP WEB are included as standard figure 9 Note RS 485 port and TCP IP port can not be used simultaneously I e possible communications are Modb...

Страница 18: ...verige AB reserves the right to make changes and improvements to the contents of this manual without prior notice Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 601...

Отзывы: