DESCRIPTION

The LT FL01 Series is part of the Fire Alarm Aspiration Sensing 

Technology

®

 (FAAST) family.  FAAST is an advanced fire detection 

system for use where early warning and very early warning are a 

requirement. The system continuously draws air from the controlled 

environment through a series of sampling holes to monitor the 

environment for smoke particulate.
The FL01 is the stand-alone version of the FAAST LT range and is 

available in 3 different models:

FL0111E -

 Has single channel capability with one laser smoke 

sensor.

FL0112E -

 Has single channel capability with two laser smoke 

sensors in a common chamber for coincidence 

detection.

FL0122E -

 Has two channel capability with two laser smoke 

sensors in separate chambers. (One sensor for each 

channel).

This guide provides information for mounting and basic installation 

using the unit’s default factory settings.  For more extensive 

information please see the FAAST LT Advanced Setup and Control 

Guide - reference D200-100-00.

SPECIFICATIONS
Electrical Characteristics

Voltage Range: 

18.5 - 31.5 VDC

Supply Current: 

1 Channel: 

170mA (typical); 360mA (max) @ 

24 VDC 25

o

C (excluding sounders)

 

2 Channel: 

270mA (typical); 570mA (max) @ 

24 VDC 25

o

C (excluding sounders)

Configurable Input: Activation Time: 

2s (min)

Relay Contact Ratings: 

2.0 A @ 30 VDC, 0.5A @ 30 VAC

Environmental Ratings

Temperature: 

-10°C to 55°C

Relative Humidity: 

10% to 93% (non-condensing)

IP Rating: 

65

Mechanical

Exterior Dimensions: 

See Figure 1

Wiring: 

0.5 mm² to 2 mm² max

Maximum 

Single

 Pipe Length:  

100m (Classes B & C)

Maximum 

Branched

 Pipe Length:  

160m (2 x 80m, Class C)

Maximum Number of Holes:  

See Table 1A

Pipe Spec (EN54-20 Compliance):  

to EN 61386 

 

(Crush 1, Impact 1, Temp 31)

Outside Pipe Diameter: 

25mm (nom) or 27mm (nom)

Shipping Weight: 

6.5kg (inc sensors)

FIRE ALARM ASPIRATION SENSING TECHNOLOGY

®

QUICK INSTALLATION GUIDE 

STAND-ALONE FAAST LT MODELS FL0111E  FL0112E  FL0122E

Figure 1: Dimensions and Knock-Outs

E N G L I S H

PARTS LIST
Description Quantity

FAAST LT unit 

1

Mounting bracket 

1

3-pin Terminal block  

6

4-pin Terminal block  

1

2-pin Terminal block  

3

47 k-ohm EOL Resistor  

2

USB Cable 

1

Front Panel Labelling Pack 

1

Wiring Diagram Label 

1

Installation Kit CD 

1

Quick Installation Guide 

1

Important Note

Aspirating Smoke Detectors supplied and installed within the 

EU  must  conform  to  the  EU  Construction  Products  Regulation 

(CPR) 305/2011 and the related European Product Standard EN 

54-20. FAAST LT has been tested and certified to ensure that it 

conforms to the necessary Standards, but strict adherence to this 

instruction guide is advised to ensure that the installation meets 

the requirements of the CPR.

Warning

The performance of this system is dependent upon the pipe 

network.  Any  extension  or  modification  to  the  designed 

installation may cause improper operation. The operational 

effects of such changes need to be verified using the PipeIQ 

2 design software.

367 mm

135 mm

56 mm

44 mm

403 mm

356 mm

50 mm

50 mm

60 mm

110 mm

I 56- 3888- 105

Содержание FAAST LT FL01 Series

Страница 1: ...to 93 non condensing IP Rating 65 Mechanical Exterior Dimensions See Figure 1 Wiring 0 5 mm to 2 mm max Maximum Single Pipe Length 100m Classes B C Maximum Branched Pipe Length 160m 2 x 80m Class C M...

Страница 2: ...e installer to choose the language required for the installation from the Front Panel Labelling Pack Figure 2 shows where the labels need to be placed Figure 6 Fasten the mounting bracket to the wall...

Страница 3: ...1 and or 2 6 FL0122E Channel 1 1 and or 2 Channel 2 3 and or 4 5 6 Table 1 Pipe Holes Used for Each FAAST LT Model Note 1 Pipe holes not used should be kept sealed Note 2 Do NOT glue pipes into the p...

Страница 4: ...manufacturer PLACE WIRING LABEL HERE If the FAAST LT door is closed for a long time especially at high temperatures it may be necessary to use a flat bladed screwdriver between the two tabs at the top...

Страница 5: ...e LED and relay PRE ALARM 1 or 2 Set ON when PRE ALARM CONDITION is met on channel Default condition Level 1 FAULT 1 or 2 When FAULT CONDITION on Ch1 or Ch2 or a common FAULT occurs Fault is also indi...

Страница 6: ...F L O W INITIALIZATION LEVEL SMOKE FAULT FAULT POWER 2 10 3 1 4 5 6 7 8 9 TEMPERATURE INPUT S E N S O R A S P IR A T O R DR IFT CO MP EN SA TIO N DIS AB LE SY ST EM S O U N D E R F IL T E R L O W F L...

Страница 7: ...2 LOW FLOW ON Yellow Low flow fault Check filter check pipe network for blockages SENSOR 1 BLINK Yellow Sensor initialization fault Try to restart device Replace faulty sensor 2 BLINKS Yellow Sensor c...

Страница 8: ...ake sure all power is removed from the system before removing any covers Service Mode Opening the cabinet door during normal operation will cause the unit to enter Service Mode The FILTER LEDs will bl...

Страница 9: ...l phases of operation WARNING Using compressed air to clean the pipe system High pressure air flushed through the system could damage the fan ensure that the FAAST LT unit is sealed or detached from t...

Отзывы: