CAN – Ethernet Gateway
54
©
SYS TEC electronic GmbH 2007 L-1032e_9
•
Problem:
BTP TxBuffer overflow
Possible causes:
no CANtoBTP buffer available -> message loss
Indication on Gateway:
Ethernet error LED illuminates
•
Problem:
BTP RxBuffer overflow
Possible causes:
no CANtoBTP buffer available -> message loss
Indication on Gateway:
Ethernet error LED illuminates
•
Problem:
Error during receipt or transmission via BTP
Possible causes:
e.g. if the recipient does not have a free buffer or in the
event of a timeout
General
: CANtoTCP/IP send buffer is discarded -> message
loss
Indication on Gateway:
Ethernet error LED illuminates
•
CAN bus-off error
Possible causes:
incorrect CAN bus cabling,
wrong CAN bitrate,
hardware error
Gateway:
CAN error LED blinks with a 50:50 on/off ratio until
the transmission or receipt of a CAN message was
successful
Содержание GW-003
Страница 1: ...system house for distributed automation CAN Ethernet Gateway GW 003 Systems Manual Edition April 2007 ...
Страница 5: ...Contents SYS TEC electronic GmbH 2007 L 1032e_9 Index 97 ...
Страница 8: ...CAN Ethernet Gateway SYS TEC electronic GmbH 2007 L 1032e_9 ...
Страница 14: ...CAN Ethernet Gateway 6 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Страница 56: ...CAN Ethernet Gateway 48 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Страница 66: ...CAN Ethernet Gateway 58 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Страница 100: ...CAN Ethernet Gateway 92 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Страница 108: ...Published by SYS TEC electronic GmbH 2007 Ordering No L 1032e_9 Printed in Germany ...