STRATABOX
™
Operations and Maintenance Manual
INSTALLATION 2-3
©
2006 SyQwest Incorporated
Accessories and Options
The following items are available to complement and enhance the operation of the StrataBox Profiler.
Please contact your authorized SYQWEST distributor or visit our web site for information and assistance
in obtaining any of these items.
Product
Code
Item
Quantity
P02553
TDU-850 Thermal Printer
1
P03100
TDU-1200 Thermal Printer
1
P03120 TDU-2000F
Thermal
Printer
1
P03050
12 Channel DGPS System w/ Combo Antenna
1
P04465 Over-the-Side
Mounting
Kit
1
Table 2-2 Accessories and Options
2.1.2 - Installing the StrataBox Electronics
Instructions are provided in this section regarding the physical installation of the StrataBox Sensor Unit
and the PC that is used for the User Interface. Guidelines are provided for locating and/or mounting the
StrataBox Sensor unit and the PC. The installer should refer to Section 2.1.4 for information on electrical
hookup.
Selecting a Location for the Electronics
The StrataBox Sensor Unit is designed for portable, marine applications but maybe used in permanent
installations as well. The user must determine if the StrataBox Sensor Unit is to be mounted on the vessel
or just placed in a convenient place on-board the vessel. Either way the appropriate location for the unit
needs to be determined. The following considerations should be investigated before deciding upon a
location:
1. User Supplied Personal Computer
The first step in the equipment location process is to determine the optimum place for viewing the data.
The unit should be positioned to provide the optimum viewing angle and within easy reach of the operator
whenever possible. This will vary depending on the size of the vessel and type of Personal Computer
(Desktop or Laptop) but is most important to insure the comfort and success of the user. The location
selection should consider that standard PC displays are not easily readable in direct sunlight. Adequate
space for the computer and any peripherals that need to be connected should be considered as well.
Finally, provisions need to be made to properly secure the equipment for the worst sea conditions that
may be encountered.
2. Cable Lengths.
Both the Data Interface Cable and the DC Power Cable supplied with the product are 10 feet long. Thus,
the Sensor Unit must be installed within 10 feet of both the user supplied Personal Computer and a 10-
30VDC Power Source. The unit must also provide adequate access for cabling termination without
binding, and allow suitable space for servicing the equipment. (If necessary, the data cable may be
extended beyond 10 feet. See Section 2.1.4 for more information)