Synway Information Engineering Co., Ltd
Figure 3-19 Modify FXS Port
The table below explains the other configuration items on the FXS port modification interface.
Item
Description
Register Port
To register the port to the SIP server.
Password
Registration password of the port. To register the port to the SIP server, both
configuration items
SIP Account
and
Password
should be filled in.
This configuration item is valid only when the
Auto Dial Number
is not left empty. If
there is no dialing operation after pickup within the time period set by this item, the
port will automatically call the
Auto Dial Number
.
Wait Time before
Auto Dial
This configuration item is valid only when the
Call Forward
feature is enabled and
the
Forward Type
is set to
No Reply
. If the corresponding station does not pick up
the incoming call within the time period set by this item, the port will forward the call
to the preset
Forward Number
.
Time for No Reply
Forward
After configuration, click
Modify
to save the settings into the gateway, click
Reset
to restore the
configurations, or click
Cancel
to cancel the settings.
SMG Series Analog Gateway User Manual (Version 1.0)
Page 24