Loss of Power

  

 

Console power failure 

 

Ensure console in plugged in and 

repeat “pairing instructions” found on 

set up section.  

 

 

 

Technical Specifications  
 

FCC ID:  

WIRELESS-HC: 2AYUW-WHC1 
RECEIVER-HC: 2AYUW-RHC1 
 

IC:

  

WIRELESS-HC: 27015-WHC1 
RECEIVER-HC: 27015-RHC1 
 
The devices comply with the following standards: 
 
FCC 47CFR PT 15.247 Issued:2004/10/01  
Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. 
All measurement performed in 10m chamber. 
 
FCC 47CFR: (Part 15 Subpart B) 
Title 47 CFR Part 15 Subpart B: Unintentional Radiators 
Concurrently with FCC Part 15.247 
 
RSS-247 
Issue: 2015/05/22 Issue 1 Digital Transmission Systems (DTSs), 
Frequency Hopping Systems (FHSs) and License-Exempt Local Area Network (LE-LAN) Devices 
Concurrently with FCC Part 15.247 
 
RSS 102:2015 Ed.5 
Radio Frequency (Rf) Exposure Compliance of Radiocommunication 
Apparatus (All Frequency Bands) 
Concurrently with FCC Part 15.247 
 
IC ICES-003:2016Ed.6 
Information Technology Equipment (Including Digital Apparatus) 

 Limits and Methods of Measurement 

Concurrently with FCC Part 15.247 
 
ETSI EN 300 328:2019 Ed.2.2.2 
Wideband Transmission Systems; Data Transmission Equipment Operating in the 2,4 GHz band; Harmonized 
Standard for Access to Radio Spectrum 

 

ETSI EN301489-1:2017Ed. V2.1.1 
Electromagnetic Compatibility (EMC) Standard For Radio Equipment And Services; Part 1: Common Technical 
Requirements; Covering The Essential Requirements Of Article 3.1(B) Of Directive 2014/53/Eu And The 
Requirements Of Article 6 Of Directive 2014/30/Eu 
Includes: 
ETSI EN 301 489-17 V3.1.1 (2017-02) 
ETSI EN 303 446-1 V1.2.1 (2019-07) 
 
EN IEC 62311:2020 Testing and/or Evaluation 
 

Receiver for Wireless Hand Control, EG1A and Wireless Hand Control, EG1A intentionally receive RF 
electromagnetic energy for the purpose of its operation:  

 

Frequency band of reception: 2405MHz to 2475MHz 

 

Receiving bandwidth: 20dB bandwidth: 2.8MHz 

Содержание ANSPACH EG1

Страница 1: ...d for cutting and shaping bone including the cranium and spine Contraindications The eG1 High Speed System does not have any known product specific contraindications Potential Adverse Events As with a...

Страница 2: ...ction causing delay in surgery The Hand Control is provided sterile Remove product from the package using established operating room procedures for sterile transfer Store sterile devices in their orig...

Страница 3: ...its packaging is compromised Visually inspect device components for damage before using do not use if damage or wear is evident unrecognizable markings missing or removed part numbers corrosion etc M...

Страница 4: ...rical Equipment Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the eG1 system Othe...

Страница 5: ...e field Caution Do not push receiver connector into console connector port when out of alignment Figure 1 Receiver connects to the foot control connector port on console SC3001 or SC3002 3 Remove the...

Страница 6: ...dpiece and release pressure on button to decrease speed of handpiece Warning Keep hand control safety cover in locked position when not in use Figure 5 Hand control cover shown in unlocked position 6...

Страница 7: ...st All Instrument System components returned should be properly cleaned as applicable prior to shipping to the manufacturer Warning Transmissible Spongiform Encephalopathies TSE DePuy Synthes Power To...

Страница 8: ...ator will be solid blue Out of Range The blue light indicator will blink with a fast flash when device is out of range or the signal is lost due to interference Hand Control Battery is at FULL Capacit...

Страница 9: ...ure device maintain a minimum distance between portable and mobile RF communications equipment transmitters and the eG1 System as recommended in the Recommended separation distances between portable a...

Страница 10: ...mmunication Apparatus All Frequency Bands Concurrently with FCC Part 15 247 IC ICES 003 2016Ed 6 Information Technology Equipment Including Digital Apparatus Limits and Methods of Measurement Concurre...

Страница 11: ...e IEC 60601 1 6 Issued 2013 10 29 Ed 3 Medical Electrical Equipment Part 1 6 General Requirements for Basic Safety and Essential Performance Collateral Standard Usability Amendment 1 IEC 60601 1 2005...

Страница 12: ...tic establishments and those directly connected to the public low voltage power supply network which supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluc...

Страница 13: ...r 25 periods 50Hz 30 periods 60Hz Interruptions 0 UT 100 dip in UT for 250 periods 50Hz 320 periods 60Hz Mains power quality should be that of a typical commercial or hospital environment If the user...

Страница 14: ...magnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3...

Страница 15: ...M 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation b 217 Hz 2 0 3 28 1 845 1 970 2 450 2 400 2 570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse Modulation b 217 Hz 2 0 3 28 5 240 5 100 5 80...

Страница 16: ...stimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At...

Страница 17: ...DePuy Synthes Representative for more information All DePuy Synthes Implant Instructions for Use as well as general Instructions for Use are available as PDF files at www e ifu com www depuysynthes c...

Отзывы: