STYLITIS-10 INSTALLATION GUIDE [0516]
6
3.
REED ANEMOMETERS OR RAIN GAUGES.
Switch-type sensors (reed):
Anemometers: VECTOR A100R, NRG #40H.
Rain Gauges: NRG RainGage, YOUNG Tipping Bucket
CONNECTION:
Connect the first anemometer or rain gauge to screws 1 [CH1] and 2
[GND] on the left screw terminal.
Connect the second anemometer or rain gauge to screws 6 [CH8] and 5
[GND] on the right screw terminal. If you are using a datalogger with
Serial Number starting with ‘026A’, connect a 20kΩ pull-up resistor for
CH8, between [CH8] and external power supply 12 V [+BAT Ext].
Wire polarity does matter only for NRG’s #40H anemometer. In the
connection figure below, the signal pin (CH1/CH8) is the white one, the
[GND] pin is the black one, while connect the red one as well to the 12V
power supply [+BAT Ext].
Typical wire size: 2 x 0,25 mm
2
(shielded cables are recommended).
Connect the shield to the GROUND screw and the metal body of the
anemometer (if plastic, leave it unconnected).
IN CASE IT DOESN’T WORK:
Check that the anemometer or rain gauge rotates freely and that its axle
is straight.
With a multimeter check the resistance in the sensor’s terminals: it
should change from short circuit to open circuit while moving or rotating.
REED-SWITCH
ANEMOMETER-
RAIN GAUGE
REED-SWITCH
ANEMOMETER-
RAIN GAUGE
1 2 3 4 5 6 7 8
LEFT SCREW TERMINAL
G
ND
CH2:
A
in
/Di
n/Do
ut
CH3:
A
in
/Di
n/Do
ut
G
ND
CH4:
A
in
/Di
n/Do
ut
+
V
P
u
ls
ed
O
ut
A
UX
CH1: C
in/D
ou
t
1 2 3 4 5 6 7 8
RIGHT SCREW TERMINAL
G
ND
CH6:
A
in
/Di
n/Do
ut
CH7:
Ain
/Di
n/Do
ut
G
ND
CH8:
A
in
/Di
n/Do
ut
-B
A
T
E
x
t\
G
ND
+
B
A
T
E
x
t
CH5:
A
in
/Di
n/Do
ut
20k
Ω
Connect 20k
Ω
only for Serial
Numbers
‘026Axxxx’
Содержание Stylitis-10
Страница 1: ...STYLITIS 10 INSTALLATION GUIDE ...