2.
LOW-LEVEL AC ANEMOMETER.
Sinusoidal output sensors: NRG’s MAX#40, YOUNG’s 05103 (for
connections refer to instruction sheet).
CONNECTION (MAX#40):
Connect the anemometer to screws 1 [CΗ1] and 2 [GROUND] on the left
screw terminal. (CH8 is not suitable for sinusoidal output sensors)
Wire polarity does matter (see drawing). Typical wire size: 2 x 0,25 mm
2
(shielded cables are recommended). Connect the shield to the GROUND
screw. Do not connect the shield to the anemometer.
IN CASE IT DOESN’T WORK:
Check that the anemometer rotates freely
and that its axle is straight.
With a multimeter check the resistance in
the anemometer’s terminals. It must be
less than 1000
Ω and greater than 400Ω.
Rotate the anemometer and measure the
AC voltage on its terminals; it should
generate at least 200mV.