STYLITIS-10 INSTALLATION GUIDE [0516]
26
SETUP:
Click ‘Read Inputs Setup’ in the ‘Setup’ tab, in the ‘Data logger online’ bar on the left.
Open an analog channel’s node, eg CH2.
Click the MEASURE line and select
‘Solar Radiation Direct beam’, ‘Solar Radiation
Global’ or ’ Solar Radiation Diffused’, according to the type of solar radiation you are
measuring.
Click the SENSOR line and select
‘LI-200SZ’, if you are using the sensor without an
amplifier or
‘LI-200SZ+Pyranometer Amp’, if you are using it with an amplifier.
The channel type (first line), along with the Slope, Offset are automatically updated.
You can also change the units by clicking the UNITS line. The Slope and Offset are
automatically updated again.
In order to save the changes, click
‘Write Setup’ in the ‘Setup’ tab, in the ‘Data logger
online’ bar on the left. If you wish to change the setup of multiple channels, one
‘Write Setup’ in the end is enough.
ΝΟΤΕ: For calibrated sensors, you can enter the correct SLOPE και OFFSET values
in retrospect.
Connect serially via Opton 4. (Connect the
computer’s COM port to the datalogger’s
PERIPHERAL port).
Before changing the setup select:
ACQ OFF
.
After changing setup select:
ACQ ON
to start acquisition (data logging).