SETUP:
Click ’Read Inputs Setup’ in the ‘Setup’ tab, in the ‘Data logger online’ bar on the left
For the
elevation
sensor, open an analog channel’s node eg CH2.
Click the MEASURE line and select
‘‘Elevation Angle’.
Click the SENSOR line and select
‘Tiltometer_Elevation_2.5V’.
The channel type (first line), along with the Slope, Offset are automatically updated.
Connect serially via Opton 4. (Connect the
computer’s COM port to the datalogger’s
PERIPHERAL port).
Before changing the setup select:
ACQ OFF
.
After changing setup select:
ACQ ON
to start acquisition (data logging).