22
4036B Operations and Maintenance Manual Rev. E
Appendix A: Specifications
A.1 Electrical Specifications
Table 3
lists the electrical specifications for the 4036B.
Table 3: Electrical specifications
Item
Specification
Protection Class
Class I (Grounded Type)
Power Input Voltage
90 – 264 VAC 47 – 63Hz, 0.5 A
Note:
Fluctuations not to exceed ± 10% of nominal supply voltage.
Caution:
The above AC Power Supply specification reflects the
overall Power Supply ratings. For UL and CE compliance the
Power Supply must only be operated at 100 – 240 VAC, 50-60 Hz.
Power Inlet Type
IEC 60320 sheet C14
Power Supply Cord Set
18 AWG (0.75 mm
2
minimum)
Power Mains Fuse
(2) - 250V~1A Time lag 5x20 mm
Signal Input and output
Frequency 1 – 20 MHz
Impedance: 50
Ω
±
5
Ω
Input level 0- 1 V rms (13 dBm)
Connectors
Input: 1 BNC
Output: 15 BNC
LAN: RJ-45
Gain
Factory setting is 1.0 ± 10%, can be changed via internal jumper settings to -1,
+1 or +2 dB
Isolation
> 100dB (with 5 MHz signal)
Spurious distortion
< - 80 dBc (with 5 MHz signal)
Harmonic distortion
< - 40 dBc (with 5 MHz signal)