1
TimeSource 3100
153
TL1 Reference
097-72020-01 Issue 9: November 2003
2
5
3
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
44
Retrieve Communication (cont’d)
Parameter
Value
Parameter Description
AUTOLOGOFF=a
a = 1 to 255
Inactive minutes until the unit logs off the
user, keeping the connection open
a = 0
Autologoff is disabled
SWCONTROL=a
a = ALW
XON/XOFF flow control is enabled
a = INH
XON/XOFF flow control is not enabled
HWCONTROL=a
a = ALW
Serial port CTS/RTS flow control is
enabled
a = INH
Serial port CTS/RTS flow control is not
enabled
BAUD=a
a = 115
Serial port baud rate is 115 kbaud
a = 57.6
Serial port baud rate is 57.6 kbaud
a = 38.4
Serial port baud rate is 38.4 kbaud
a = 19.2
Serial port baud rate is 19.2 kbaud
a = 9600
Serial port baud rate is 9600 baud
a = 4800
Serial port baud rate is 4800 baud
a = 2400
Serial port baud rate is 2400 baud
PARITY=a
a = EVEN
Even parity bit is enabled
a = ODD
Odd parity bit is enabled
a = NONE
Parity bit is disabled
STOP=a
a = 1
1 stop bit
a = 2
2 stop bits
Содержание TimeSource 3100
Страница 1: ...TimeSource 3100 GPS Primary Reference Source 097 72020 01 Issue 9 November 2003 ...
Страница 49: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Страница 109: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Страница 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...