Choose the alarm parameters as desired. A description of each setting
follows:
SettingDescription
Severity 1The initial severity of the alarm.
Service Affecting 1The initial service affecting status of the alarm condition.
Time to Severity 2If the Escalate Alarm check-box is selected, the alarm
will be escalated to the severity and service affecting status selected under
Severity 2 and Service Affecting 2, after the time period selected under
Hours and Mins has been reached. If the Escalate Alarm check-box is not
selected, the alarm will not be escalated.
Severity 2The severity of the alarm after it has been escalated.
Service Affecting 2The service affecting status of the alarm condition after
the alarm has been escalated.
When you are finished modifying the alarm parameters, click the Next>>
button.