Craft Port
To provide an RS-232 link for TL1 command access to the TimeSource 3000, connect to the
craft port at the female RJ-45 connector labeled Craft on the front panel. A Craft-port-to-PC
cable is supplied with the TimeSource 3000 for making this connection. See Figure 11 for
the location of the connector, and Table H for the connector pinouts.
The Craft connector transmits data on pin 2, and receives data on pin 3. Be sure the other
equipment receives data from the transmitting pin, and transmits data to the receiving pin.
Note: Pins not listed are reserved for future use.
Table H. Craft Pinouts
Pin
Signal
Abbreviation
Direction
2
Transmit data
TXD
From TimeSource 3000
3
Receive data
RXD
To TimeSource 3000
5
Signal ground
GND
—
6
Data terminal ready
DTR
From TimeSource 3000