Page 18
COUGH
DUMP PROFANITY
START DELAY
EXIT DELAY
Default configuration programming procedure
The 610 default configuration is set from the front panel. The process involves placing the 610 in
programming mode and selecting one of six possible configurations. It is not necessary to remove
the unit from the equipment rack, or to remove the top cover to configure or re-configure. The
unit must be powered up and not in use.
Please note - the 610 cannot be configured while opera-
tional!
The configuration settings are nonvolatile. Should power go down, the last configuration setting
is maintained. To program the 610 default configuration, proceed as follows:
Step #1 - Place 610 in BYPASS mode -
Use the STATUS button at the left end of the 610 front
panel to place the 610 in BYPASS mode.
Step #2
-
Initiate Programming Mode
- Press all four front panel lighted push buttons (EXIT
DELAY, START DELAY, COUGH, DUMP PROFANITY) and hold until all four lights come on
(approximately five seconds). When you release the buttons all four will flash, indicating that the
610 is in programming mode.
X
X X
X
Step #3
-
Select Desired Option
- While all four lights continue to flash, select your option by
pressing a button or combination of buttons as indicated in the table on the following page. The
associated light(s) flash to confirm your selection. After several seconds the light(s) will stop
flashing, indicating that the 610 has left the programming mode.
Step #4 - Return 610 to OPERATE mode
- Use the STATUS button at the left end of the 610