Operating elements
1
10
11
12
13
14
2
3 4
5
6
7
8
9
1 Mains cable with mains plug
8 Front protective grille
2 Control panel (with colour-coded buttons)
9 Fixing screw (protective grille)
3 Rear protective grille
10 Nut
4 Fixing screws (control panel)
11 Silent block
5 Motor
12 Screw
6 Locking screw (rotor)
13 Base
7 Rotor blade
14 Feet (anti-slip)
Operation
a) Mounting location
• Carry the product using the handle on the top of the rear protective grille (3). Place the fan with the
base (13) on a dry, clean, horizontal and secure surface.
b) Turning the fan on/off and adjusting the fan speed
• Connect the mains cable with the mains plug (1) to a suitable mains socket.
• Use the control panel (2) to control the fan. To turn the fan on, press one of the grey buttons on the control
panel.
• Press another grey button to change the fan speed.
- Light grey button (low fan speed)
- Dark grey button (medium fan speed)
- Black button (high fan speed)
• To turn off the fan, press the white on/off button on the control panel.
c)
Adjusting the direction of the air flow
•
You can adjust the direction of the air flow manually by holding the protective grille and moving it up or
down. The maximum vertical tilt angle is 120° in both directions.
• Check that the screw (12), nut (10) and silent block (11) are properly secured to the base (13) and the
protective grille to ensure that the fan can rotate properly and to prevent the fan from moving by itself
due to vibrations. If the connection becomes loose, tighten the nut (10), taking care not to overtighten it.
• Only adjust the position of the fan when it is turned off, especially when using tools. Do not use any force.
Care and cleaning
a) General information
• Turn off the fan before cleaning and disconnect the mains plug from the mains socket.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could damage the
casing or even impair the functioning of the product.
• Wipe the fan components regularly with a dry dust cloth (including the protective grilles (3 & 8) and the
base (13)).
• If you are not going to use the product for a long time, cover it and store it in a dry location away from
direct sunlight.
• Check whether any screws have become loose on a regular basis. If necessary, tighten the screws with a
screwdriver (caution: always turn off the fan and unplug it from the mains!).
b) Cleaning the rotor blade and protective grille
Danger of injury! The rotor blade has sharp edges.
• Before disassembling the fan, place it on its back.
• Open the protective grille: loosen the hinged locks and remove the screw (9) from the bottom using a
suitable Phillips screwdriver. You can now separate and remove the front and rear protective grilles.
• The front and rear protective grilles (3, 8) and the rotor blade (7) can be wiped clean using a damp cloth.
• Dry all components carefully after cleaning and before reassembly.
• Proceed in reverse order to reassemble the fan. Secure the protective grilles in place using the Phillips
screw and nut. The screw holes on both grilles must be aligned with each other.
• Close the hinged locks.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household
waste. At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
Technical data
Item no. 1430245
Power supply ........................................................220 - 240 V/AC, 50 Hz
Power consumption ..............................................55 W
Protection class ....................................................I
Overheat protection (motor) .................................yes
Temperature rise (motor) ......................................
≤75 K (after 4 h of continuous use)
Noise level ............................................................56 dB
Vertical tilt angle (fan) ...........................................120º
Air flow (fan)
.........................................................max. 65 m³/min (3900 m³/h)
Rotor diameter ......................................................30 cm
Cable length .........................................................Approx. 2 m
Operating conditions .............................................+10 to +40 °C, 10 – 80 % RH (non-condensing)
Storage conditions ................................................0 to + 50 °C, 10 – 80 % RH (non-condensing)
Dimensions (W x H x D) .......................................395 x 380 x 195 mm
Weight ..................................................................3.1 kg
Item no. 1430246
Power supply ........................................................220 - 240 V/AC, 50 Hz
Power consumption ..............................................140 W
Protection class ....................................................I
Overheat protection (motor) .................................yes
Temperature rise (motor) ......................................
≤75 K (after 4 h of continuous use)
Vertical tilt angle (fan) ...........................................120º
Air flow (fan)
.........................................................max. 100 m³/min (6000m³/h)
Rotor diameter ......................................................50 cm
Cable length .........................................................Approx. 2 m
Operating conditions .............................................+10 to +40 °C, 10 - 80 % RH (non-condensing)
Storage conditions ................................................0 to + 50 °C, 10 - 80 % RH (non-condensing)
Dimensions (W x H x D) .......................................590 x 590 x 195 mm
Weight ..................................................................5.52 kg