26
Transponder is not recognised
•
Make sure you hold one transponder in front of the RFID sensor at a time (see section 6, clause 3).
•
Ensure the transponder is close enough (approx. 3 cm) to the access system.
•
Only EM transponders with a frequency of 125 kHz can be used.
•
Metal objects can adversely affect a transponder's functionality (for example, if you keep the transponder in a wallet
with metal coins).
New user transponder cannot be paired
•
Make sure you hold one transponder in front of the RFID sensor at a time (see section 6, clause 3).
•
Ensure the transponder is close enough (approx. 3 cm) to the access system.
•
Only EM transponders with a frequency of 125 kHz can be used.
•
The memory is already occupied. Use another memory cell or clear the existing one before pairing another tran-
sponder on the same memory cell.
• To save the transponder in a specific memory cell, enter the memory cell number without leading zeros (for exam
-
ple: for memory cell number 16, enter “16” instead of “0016”).
•
When the Wiegand controller uses a MIFARE
®
smart card reader, new transponders can only be paired via this
card reader.
•
When the Wiegand controller uses a card reader for 125 kHz transponders, pairing can be performed both via the
access system and the external card reader. Use an external card reader to check the functionality.
Changeover contact is permanently active (and cannot be switched back)
•
The changeover contact activation time has been set to “0” and is in toggle mode. Each valid access attempt via
the user transponder changes the changeover contact switch position.
Resetting to factory defaults does not delete any user transponders
•
This is normal. All user transponders can be deleted by following the instructions described in section 8. e).
Wiegand connection does not work
•
Make sure the two data cables D0 and D1 are not swapped; D0 must always be connected to D0 and D1 must
always be connected to D1. Other connections can be carried out as shown in section 7. b). Always follow the
operating instructions for the external card reader.
•
Both card readers for 125 kHz transponders and card readers with MIFARE
®
smart card technology (13.561 MHz)
are supported.
Power is supplied, but the LED does not light up in standby
•
Switch on LED indications as described in section 8. i).
Access system emits no beeps
•
Switch on beeps as described in section 8. i).