23
10. Operation
a) Getting started
Power on the access system once it has been connected and installed. After powering on, the access system will emit
a beep and the red LED will glow steadily (standby).
The access system is now ready for use and can be programmed.
If the access system continuously emits beeps with the LED flashing quickly, it means that the brightness
sensor on the back has activated tamper protection and disabled all functions.
If this is the case, disconnect the access system from the power supply. Make sure that the brightness
sensor is not exposed to light beams after installation.
If you want to briefly check the access system before installation, make sure you cover the brightness sen
-
sor on the back, for example, with a piece of non-transparent adhesive tape; if necessary, briefly disconnect
the access system from the power supply to reset tamper protection.
You should take the following steps:
• Create a table and fill in all settings and user/transponder numbers.
• Switch on the IR remote control by first removing the protective strip from the battery holder or inserting the battery.
•
Think of a master code (consisting of 6 digits) and programme it (see section 8. b). The default master code is
“123456” (the same applies after resetting the access system to factory defaults).
•
The included master transponder (e.g. marked as “Master Card”) is used only for quick saving or deletion of user
transponders. The IR remote control serves for all other programming operations.
•
If you no longer wish to use the master transponder, for example, for security reasons, you can reset the access
system accordingly, as described in section 8. j). In this case, user transponders can only be paired or deleted via
the IR remote control.
•
Pair user transponders with the access system (see section 8. e).
•
Set the changeover contact activation time (see section 8. f) to be used e.g. for switching a door lock (default set-
ting is 5 seconds).
•
Check whether the saved user transponders can unlock the door lock.
•
You can programme other functions, for example, enable protection against incorrect entries (section 8. g/h) or
enable/disable LED indications or beeps (section 8. i).