2-14
Configuring the ISDN and analog interfaces
4.
Plug the cable in again and start the device.
A change to the software configuration is also necessary if the ISDN
interfaces are to be set to a different mode. If devices are to be
connected to an ISDN interface which is set differently to its default
settings, the supplied adapter must be used. This adapter serves to
cross-over the contacts in the ISDN interface.
2.5.3
Protocol setting
Parameters for the ISDN interfaces are entered into LANconfig in the
configuration area 'Interfaces' on the 'WAN' tab. Under WEBconfig,
Telnet or SSH client you will find the settings for the ISDN interface
parameters under
Setup/Interfaces/WAN
.
Select the protocol for each ISDN interface according to its
application and the ISDN connection type: Point-to-multipoint and
point-to-point connections can be used in various combinations at a
Swyx VoIP Router. The following options are available:
9 +
10
ISDN 1 Rx/Tx
(100
Ω
bus termina-
tion)
down
(off)
ISDN 1 Rx/Tx
(100
Ω
bus termina-
tion)
down
(off)
SwyxConnect 1724
DIP
Meaning
Default
1 + 2 ISDN 4 Rx/Tx
(100
Ω
bus termina-
tion)
up (on)
3 + 4 ISDN 3 Rx/Tx
(100
Ω
bus termina-
tion)
up (on)
5 + 6 ISDN power relay
ISDN 1 > ISDN 3
down
(off)
7 + 8 ISDN 2 Rx/Tx
(100
Ω
bus termina-
tion)
down
(off)
9 +
10
ISDN 1 Rx/Tx
(100
Ω
bus termina-
tion)
down
(off)
SwyxConnect 1722
SwyxConnect 1723
DIP
Meaning
Default Meaning
Default