11
PVD2000 / PVS / PVM
D
ok
: 101503A
-GB 1931
MAINTENANCE
ACCEPTED WEAR FOR DIAMETERS AND LENGTHS OF THE POKERS.
MODEL
DIAMETER
(mm)
LENGHT
(mm)
SVM 25
23,5 (25)
310 (220)
SVM 40
36 (38)
330 (335)
SVM 48
45,5 (48)
355 (360)
SVM 58
55,5 (58)
360 (365)
A. The minimum dimensions are bold printed.
B. The dimensions into brackets are the original dimensions.
C. Replace the housing when reach the minimum diameter.
D. Replace the end cap when reach the minimum length.
Note! Always use SWEPAC original parts
1. Only an expert shall work on the electrical part.
2. Make sure that the electricity is off during repairs.
3. In all maintenance operations, original parts will be used.
4. A periodic lubrication of the converters’ bearings is not necessary.
5. Every 100 hours carbon brushes should be inspected .They should be changed if effective length is
less than 5 mm.
6. Clean the ventilation vents in the front and back part of the motor periodically to avoid
overheating.
7. Check that the filter is situated in the air intake, under the switch. If it is soiled, change it. To do
this, just pull the old filter downwards and introduce a new one in the same position that the old one
was.
8. After maintenance and service works, all safety devices should be assembled correctly.
9. Every 12 months or more frequently, depending on the usage conditions, it’s recommended an
inspection be done by an authorized dealer.
10. Clean the filter often or replace it if necessary.
PERIODIC MAINTENANCE OF MOTOR (Inside the drive unit)