GB.GOLDLP.170830
www.swegon.com 71
We reserve the right to alter specifications without notice.
Available static pr
essure, Pa
Air flow
, m
3
/s
The lower limit for the airflow when the unit is operating in the airflow
regulation mode.
Recommended range for the design working point.
Permissible operating range when the fan is contr
olled to operate at a lower speed.
If pr
essur
e r
egulation is used, the airflow can be r
egulated to zer
o, however this
pr
esupposes a certain static pr
essur
e dr
op in the ducting (appr
ox. 50 Pa).
Permissible operating range in accor
dance with r
egulation 1253/2014
W
orking point with the highest air flow shall be found within the permissible ar
ea. In
case of unbalanced air flows; mean working point, supply extract shall be used.
W
orking points with less air flow is allowed to be found outside the permissible range
e.g. in case of variable air flow
.
Max. limit, Ecodesign 2016.
Outer limit - largest permissible air flow at maximum speed.
Remaining outer limits.
Recommended average working point.
Thermal efficiency
Nominal flow rate
Effective electric power
SFPint
Face velocity
Nominal external pressure
Internal
pressure drop vent. comp.
Overall fan efficiency (EU) No 327/2011
Maximum external leaking rate
Maximum internal leakage
Energy
performance
of filters
Casing
sound power level, LwA
%
m³/s
kW
W/(m³/s)
m/s
Pa
Pa
%
%
%
kWh/year
dB(A)
Red
Min. - low
NRVU, BVU
variable speed
Other
71
0,08
0,04
495
0,4
0
24
59,3
-
-
-
18
Red
Min. - high
NRVU, BVU
variable speed
Other
71
0,08
0,54
166
0,4
994
24
59,3
-
-
-
58
Yellow
Average
NRVU, BVU
variable speed
Other
81
0,34
0,42
647
1,6
300
148
59,3
-
-
-
48
Blue
Max. - high
NRVU, BVU
variable speed
Other
79
0,49
0,67
1244
2,4
241
255
59,3
5
1
2170
52
Red
Max. - low
NRVU, BVU
variable speed
Other
79
0,49
0,54
1463
2,4
0
255
59,3
-
-
-
52
Red
Min. - low
NRVU, BVU
variable speed
Other
71
0,08
0,04
491
0,4
0
24
59,3
-
-
-
17
Red
Min. - high
NRVU, BVU
variable speed
Other
71
0,08
0,54
164
0,4
994
24
59,3
-
-
-
58
Yellow
Average
NRVU, BVU
variable speed
Other
81
0,34
0,42
624
1,6
300
143
59,3
-
-
-
48
Blue
Max. - high
NRVU, BVU
variable speed
Other
79
0,50
0,67
1206
2,4
243
244
59,3
5
1
2200
52
Red
Max. - low
NRVU, BVU
variable speed
Other
79
0,50
0,53
1433
2,4
0
244
59,3
-
-
-
52
Red
Min. - low
NRVU, BVU
variable speed
Other
66
0,10
0,03
0
0,4
0
24
65,8
-
-
-
19
Red
Min. - high
NRVU, BVU
variable speed
Other
78
0,10
0,89
1248
2,5
211
277
65,8
-
-
-
55
Yellow
Average
NRVU, BVU
variable speed
Other
80
0,48
0,60
613
1,7
350
157
65,8
-
-
-
50
Blue
Max. - high
NRVU, BVU
variable speed
Other
78
0,72
0,89
1248
2,5
211
277
65,8
1
1
2930
55
Red
Max. - low
NRVU, BVU
variable speed
Other
78
0,72
0,73
1417
2,5
0
277
65,8
-
-
-
55
Red
Min. - low
NRVU, BVU
variable speed
Other
66
0,10
0,03
0
0,4
0
23
65,8
-
-
-
19
Red
Min. - high
NRVU, BVU
variable speed
Other
78
0,10
0,88
1142
2,6
220
246
65,8
-
-
-
55
Yellow
Average
NRVU, BVU
variable speed
Other
80
0,48
0,58
553
1,7
350
141
65,8
-
-
-
50
Blue
Max. - high
NRVU, BVU
variable speed
Other
78
0,73
0,88
1142
2,6
220
246
65,8
1
1
3090
55
Red
Max. - low
NRVU, BVU
variable speed
Other
78
0,73
0,71
1323
2,6
0
246
65,8
-
-
-
55
Working poin
t
Part of information requirements for NRVU according to Regulation (EU) No 1253/201
4
In and outlet connections
Colour
Remark
AHU type
Type of drive
Type of HRS
Size
Duct
Full face
05
08
Duct
Full face