background image

Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety 
information. Failure to comply with instructions could result in personal injury and/or property damage!

1

Ceiling Exhaust and Inline Fans

Model SP

Model SP is a direct drive ceiling exhaust fan designed 
for clean air applications where low sound levels are 
required. Many options and accessories are available 
such as lights, motion detectors, ceiling radiation 
dampers and speed controls. Capacities range from 25 
to 1,600 cfm (42 to 2,718 m

3

/hr) and 1 in. wg (248 Pa). 

AMCA Licensed for Sound and Air Performance.

ENERGY STAR

®

 Certified models include: 

SP-A, 50, 70, 90, 200, 250, 290 and 410; 
SP-B, 50, 70, 80 and 90.

Model CSP

Model CSP is a direct drive inline exhaust fan designed 
for clean air applications where low sound levels are 
required. Capacities range from 70 to 3,800 cfm (119 to 
6,456 m

3

/hr) and 1 in. wg (248 Pa). AMCA Licensed for 

Air Performance.

WARNING!

To reduce the risk of fire, electric shock, or injury to 
persons, observe the following:

• Suitable for use with solid state speed controls.

• Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer.

•  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

• Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction.

• Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as 
those published by the National Fire Protection Association 
(NFPA), and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code 
authorities.

• When cutting or drilling into wall or ceiling, do not damage 

electrical wiring or other hidden utilities.

• Acceptable for use over a bathtub or shower when installed  

in a GFCI protected branch circuit. (Up through size SP-A390)

• Never place a switch where it can be reached from a tub or 

shower.

• Ducted fans must always be vented to the outdoors.

• These fans are not recommended for cooking exhaust 

applications. They are designed primarily for low temperature, 
clean air applications only. The diagram shows the minimum 
distance these fans should be placed in relation to cooking 
equipment.

• Fan/Light combination not to be installed in a ceiling thermally 

insulated to a value greater than R40.

CAUTION!

• For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

®

®

Document #474680

Model SP

Model CSP

Ceiling Exhaust and Inline Fans

Содержание CSP

Страница 1: ...necting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper co...

Страница 2: ...A Models Only A 50 500 710 780 Models Remove the two screws holding the power assembly in and pull power assembly out Rotate power assembly 180 degrees and put back into fan Use the same screws to reattach power assembly to fan housing Flip fan over and remove the four screws holding the discharge duct and damper assembly Exchange the assembly with plate mounted on top of fan as shown in these ill...

Страница 3: ...iation damper has an electrical plug in it The electrical plug must be inserted into the fan Make sure the electrical wire will not interfere with damper operation as shown in figure below Discharge Installation SP A 50 90 Models A 50 510 710 780 Models Wires from lighted grille Wires to ceiling fan Do not allow interference in this area A 700 900 1550 Models SP A Box Slot Plastic SP A Duct Adapter...

Страница 4: ...two SP B mounting tabs fully engage into the two SP B box mounting slots 1 2 OPTIONAL Align the pins on the TR 6x4 adaptor to the duct pin hole on the SP B 6 inch duct Push until the adaptor snaps into place 3 SP B Box Scroll Slots SP B Box Mounting Tabs SP B Box Mounting Slots TR 6x4 Pin TR 6x4 PN 473324 SP B 6 inch Plastic Duct PN 474433 SP B Plastic Duct Pin Hole SP B Box Scroll Tabs ...

Страница 5: ...height is determined shown in Fig 2 Cut hole to dimensions shown in table below 3 Installation of ductwork is critical to the performance of the fan shown in Fig 5 Straight ductwork 1 or ductwork that turns in the same direction as the wheel 2 is recommended Ductwork turning opposite the wheel direction 3 will cause turbulence and back pressure resulting in poor performance 4 Slide ductwork over t...

Страница 6: ...wn are UL and cUL listed E 33599 Attach the Grille 1 If lighted grille is being used plug wire into fan socket If lighted grille and ceiling radiation damper are being used plug wire from lighted grille into ceiling radiation damper socket Do not plug wire directly into the fan socket Make sure the wire does not interfere with the ceiling radiation damper operation 2 Attach grille with two screws ...

Страница 7: ... cleaned periodically to maintain performance Greenheck offers washable aluminum mesh filters specifically designed for these fans Please consult our SP CSP catalog for more information Flex Duct Connections Fiberglass Ductboard Remote Mounted Correct Low Sound Installation Incorrect SP and SP C Mounted Directly Overhead CSP and SP C Converted to Inline General Maintenance Suggestions Model SP CSP c...

Страница 8: ...in the Library under Warranties Greenheck SP and CSP catalog provides additional information describing the equipment fan performance available accessories and specification data Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo greenheck com Website www greenheck com Our Commitment AMCA Publication 410 96 Safety Practices for Users and Installers of Industrial and Commercial Fans provides additio...

Отзывы: