Tube Facing Tool
User’s Manual 19
Troubleshooting
Problem
Cause
Remedy
Cutting insert is causing a
“step” during facing.
The cutting insert has been
fed too far into the tube.
Take tube out of the tool and
disassemble the tool holder.
Remove chips using pliers. File down
the step.
Slowly advance the cutting insert
towards the tube during new cutting.
Cutting insert or tool holder
is loose.
Tighten the cutting insert or the tool
holder.
The tube clamp does not
clamp correctly or has too
much play.
The tube dimensions
deviate from what the tool
has been set for.
Adjust the tool according to
Adjust the
Tube Clamp
.
The motor is not running but
signal light is on.
Quick flashing light -
The restart inhibitor has
activated.
Switch the tool off and back on. For
safety reasons, the tool will not restart
automatically after a power failure.
Slow flashing light - The
carbon brushes are worn
out.
Have the carbon brushes replaced by
your authorized Swagelok sales and
service representative.
Constant light - The motor
has overheated.
Unplug the tool and allow it to cool.
Tool has excessive vibration.
Speed is too high.
Reduce the speed.
Axial or radial play in the
components.
Check that the collet set is properly
secured.
Cutting insert is loose.
Tighten the cutting insert.
The finished tube face is not
smooth or has a large burr.
Cutting insert is worn.
Replace the cutting insert.