24
where
1
s
T
F
=
,
s
F
is Sampling Frequency. RealWave uses the
“
Forward Euler
”
method, which is
simplified from Trapezoidal Method. We can write it as below :
( )
1
1
1
Tz
H z
z
−
−
=
−
<Eq.
IV-1-7>
The frequency response function of integrator is shown in the [Fig. IV-1-6].
[Fig. IV-1-6] Frequency Response of Forward Euler Integrator
[Fig. IV-1-7] Integrated Result
Discrete integrator generates offset of signal (see [Fig. IV-1-7]). We must use highpass filter for
removing the offset. The highpass filter with 10Hz cutoff frequency (2-pole Butterworth IIR Filter) is
used in RealWave. The procedure for velocity and displacement is shown in the [Fig. IV-1-8]
Integrator
Highpass filter
(10Hz)
Integrator
Highpass filter
(10Hz)
Acceleration
Velocity
Displacement
[Fig. IV-1-8] Flow-chart for integration
Discrete integrator has original error as shown in the [Fig. IV-1-9]. Specially, that error increases