![Suzuki 9 Скачать руководство пользователя страница 259](http://html.mh-extra.com/html/suzuki/9/9_service-manual_1408853259.webp)
12-10 DF9.9T/TH “K8” (’08) MODEL
PEAK VOLTAGE
Requirements for peak voltage measurement
• Remove all spark plugs to eliminate the variables at cranking speed.
• Crank with recoil starter.
• Use a STEVENS peak voltage tester, Model CD-77.
• Use the 6-pin connector test cord (Part No. 09930-89920).
Testing sequence
Tester probe
connection
Peak voltage
Tester range
Remarks
+
(Red)
-
(Black)
1 CDI output
Orange
Black
128 V or over
NEG 500
• With ignition
coil connected
• Use the 6-pin
connector test
cord.
2
Condenser charge coil
output
Green
Black/Red
15 V or over
POS 50
With CDI unit
disconnected
3
Pulser coil output
Red/Black
Black
(Ground)
0.8 V or over
SEN 5
4
Battery charge coil out-
put
Red
Yellow
5.6 V or over
POS 50
With rectifier
disconnected
Test 1
Ignition coil
Battery charge coil
Pulser coil
Test 4
CDI unit
Test 3
Condenser
charge coil
Test 2
B
R
Y
R
Y
R/B
B
B
R/B
B
G
B/R
G
B/R
O
O
Содержание 9
Страница 1: ...For 2005 model 9 9 5 0 0 9 4 J 0 1 0 1 E ...
Страница 292: ...Prepared by Service Department 1st Ed July 2004 2nd Ed January 2008 Manual No 99500 94J01 01E Printed in Japan 296 ...
Страница 293: ......
Страница 314: ...20 DF9 9T TH DF15 Serial No 110001 and later SPECIAL TOOLS 09915 63311 Compression gauge adaptor ...
Страница 319: ...Prepared by Outboard Motor Engineering Department September 2010 Manual No 99501 94J20 01E Printed in Japan 24 ...
Страница 320: ......