10
TROUBLE SHOOTING – MACHINERY
MECHANICAL TROUBLE SHOOTING AND ELECTRICAL WORKS MUST BE DONE BY QUALIFIED
PERSON(S) IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. THE OWNER OF
THE MACHINE MUST MAKE THE RISK ASSESSMENT FOR EACH TASK BELOW DETERMINING
WHAT QUALIFICATIONS ARE NECESSARY.
WARNING! THE CYLINDER ROTATES ON A TIMER FUNCTION. WHEN REMOVING THE BOLTED
COVERS OR THE HOOD THE POWER SUPPLY MUST BE SWITCHED OFF AT THE MASTER SWITCH
AND LOCKED.
THE POWER SUPPLY MUST BE SWITCHED OFF AT THE MASTER SWITCH AND LOCKED
BEFORE REPAIRING OR SERVICING THE MACHINE.
LOCKOUT/TAGOUT BEFORE REMOVING BOLTED COVERS.
Most problems or fault occurring are about the biological process in the cylinder. If there is a problem
with the machinery it almost every time results in problem with the biological process and therefore it
is very important to quickly define the problem and repair the composter.
Note! Resetting the alarm in the Operator panel only resets the Operator panel, making it possible
to adjust settings, using manual mode etc. It does not reset the fuse and does solve the actual
problem. This has to be done for each fuse/fault respectively in the electrical cabinet. If the fault
has not been taken care of, the alarm text will re-appear after a set time (default time is 5 minutes)
or when trying to run the motor and the fuse trips again.
10.1
INSPECTION DOORS AND EMERGENCY STOP
10.1.1
WARNING – INFEED HOPPER LID
When the infeed hopper lid is opened there is a small warning sign
flashing on the touch screen. When the lid is closed this warning sign
disappears. There is no need to reset the machine after opening and
closing the infeed hopper lid.
10.1.2
INSPECTION DOOR(S) OPEN
When any of the inspection door(s) on the hood is opened there is a small
warning sign flashing on the touch screen. Close the inspection doors.
W
hen the doors are locked, reset the machine using the reset button.