SiO Controller
SiO2/SiO2PNP
SiO3
SiO-N1
SiO3.2
SiOt
SiO-N3/SiO-N3PNP
Instruction Manual
Version 3.9
Страница 1: ...SiO Controller SiO2 SiO2PNP SiO3 SiO N1 SiO3 2 SiOt SiO N3 SiO N3PNP Instruction Manual Version 3 9...
Страница 2: ...Failure due to electrical or mechanical modification c Failure or damage caused by fire earthquake or other natural disaster d Any other failure or damage for which SUS is not considered responsible...
Страница 3: ...ntroller 3 9 3 3 2 Wiring to Controller 3 9 3 4 Settings 3 10 3 4 1 RUN Switch 3 10 3 4 2 Timer Setting 3 10 3 5 Input Output 3 11 3 5 1 Input Output Connectors SiO2 SiO2PNP 3 11 3 5 2 Input Output Co...
Страница 4: ...iO2PNP SiO3 SiO N1 SiO3 2 SiOt SiO N3 SiO N3PNP When using the SiO C controller see the SiO C Instruction Manual The contents of this manual are subject to change without prior notice for product impr...
Страница 5: ...ller on an incombustible object Failure to do so may cause a fire Be sure to apply each connector with the voltage specified for the connector Also connect each connector with the correct polarity Do...
Страница 6: ...N DIN rail SiO N1 8 8 NPN e CON GF N DIN rail SiO3 2 3 2 NPN e CON GF N SiOt 4 2 NPN e CON GF N DIN rail SiO N3 16 16 NPN e CON GF N DIN rail SiO N3PNP 16 16 PNP e CON GF N DIN rail See 7 Specificatio...
Страница 7: ...ht to execute the program 4 RUN LED green Lights during RUN 5 Input connectors A connector used for input e CON 4 pole 6 inputs 6 Output connectors A connector used for output e CON 3 pole 4 outputs 7...
Страница 8: ...tors A connector used for input e CON 4 pole 16 inputs 6 Output connectors A connector used for output e CON 3 pole 16 outputs 7 IN LED red Lights when the input signal is ON IN1 to IN16 8 OUT LED gre...
Страница 9: ...ed for output e CON 3 pole 8 outputs 7 IN LED red Lights when the input signal is ON IN1 to IN8 8 OUT LED green Lights when the output signal is ON OUT1 to OUT8 9 USB connector Connect the USB cable h...
Страница 10: ...hts during RUN 5 Input connectors A connector used for input e CON 4 pole x 3 inputs 6 Output connectors A connector used for output e CON 3 pole x 2 outputs 7 IN LED red Lights when the input signal...
Страница 11: ...d for output e CON 3 pole x 2 outputs 7 IN LED red Lights when the input signal is ON IN 1 to 4 8 OUT LED green Lights when the output signal is ON OUT 1 to 2 9 USB connector Connect the USB cable her...
Страница 12: ...ON 3 pole 16 outputs 7 IN LED red Lights when the input signal is ON IN 1 to 16 8 OUT LED green Lights when the output signal is ON OUT 1 to 16 9 USB connector Connect the USB cable here Micro B USB 2...
Страница 13: ...e dedicated software SiO Programmer The following four items are set 1 ON conditions Conditions for turning ON each output 2 Status Conditions or waiting time for turning ON each output 3 OFF conditio...
Страница 14: ...time The cycle time of the SiO controller is 5 msec It is constant regardless of the number of registered programs 3 2 3 Input Response Time The input ON OFF time must be set to 10 msec or more Failu...
Страница 15: ...ng to controller and power connector Connect 24 V DC to the power connector It is recommended to use the dedicated AC adapter Otherwise prepare a plug of the following size Do not supply power except...
Страница 16: ...F Be sure to set the RUN switch to STOP before registering a program from the SiO Programmer 3 4 2 Timer Setting The SiO controller has two timer setting trimmers They are used when T1 or T2 is select...
Страница 17: ...utput e CON 3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the controller Connector Input Outpu...
Страница 18: ...3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the controller Connector Input Output Signal Con...
Страница 19: ...CON 3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the controller Connector Input Output Signal...
Страница 20: ...ON 3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the controller Connector Input Output Signal...
Страница 21: ...th e CON Visit the SUS website mentioned in 5 Options Input e CON 4 pole pin arrangement Output e CON 3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively conne...
Страница 22: ...e CON 3 pole pin arrangement Pin No Signal 1 24V 2 3 0V 4 Input signal 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the controller Connector Input Output Sign...
Страница 23: ...P Input voltage 24 V DC 10 Input current Approx 7 mA 24 V DC Insulation system Non insulated When externally connecting a non contact circuit the leakage current must be 1 mA or less per point when th...
Страница 24: ...ernal circuit of this output element will be broken in the event of a load short circuit or if a current above the rated current flows When connecting an inductive load such as a relay check the load...
Страница 25: ...g are examples of connecting e CON type SiO and input output devices Connection example of NPN type 1 Connect a push button switch to IN1 2 Connect a sensor to IN2 3 Connect an LED to OUT1 Push button...
Страница 26: ...d use it For details see to SiOt Ethernet Communication Instruction Manual 3 7 1 Communication specifications Item Contents Number of channels 1 channel Communication speed 10 Mbps and 100 Mbps Commun...
Страница 27: ...e personal computer Visit the SUS website or see the SiO Programmer Instruction Manual for the use environment including supported OS and how to operate the programmer Main Functions 1 Edit programs S...
Страница 28: ...orm USB communication the USB driver must be installed For how to install the USB driver see the following instruction manual SiO Programmer Instruction Manual After USB communication disconnect the p...
Страница 29: ...for the SiO controller including various terminal blocks input output devices cables and separate connectors Input output options are not available for SiO2PNP SIO N3PNP Visit the SUS website for det...
Страница 30: ...SUS Check 2 Is the RUN switch set to RUN Action To activate the controller the RUN switch must be set to RUN Check the switch Check 3 Are the wires connected correctly Action Check the wiring of the...
Страница 31: ...10 100 mA 24 V DC Open collector NPN Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant...
Страница 32: ...mA 24 V DC Open collector PNP Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B...
Страница 33: ...A 24 V DC Open collector NPN Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B...
Страница 34: ...Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B type 485 communication SUS O...
Страница 35: ...NPN Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B type 485 communication SU...
Страница 36: ...ans of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B type Ethernet Communication specification Communication speed 10 Mbps and 100 Mbp...
Страница 37: ...rogram system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B type 485 communication SUS Ori...
Страница 38: ...Program system Creation Selection type program by means of dedicated PC software free download Language SUS Original Communication specification USB 2 0 compliant Micro B type 485 communication SUS O...
Страница 39: ...to Ver 2 00 2 Basic kits 4 to 7 added to options All pages 2 1 Apr 17 2017 SiO E deleted 1 1 2 1 3 1 3 0 Apr 27 2017 SiO2 added All pages 3 1 Aug 30 2017 SiO2PNP added All pages 3 2 Sep 29 2017 SiO3 a...