AC-LC2 Liquid Cooler Dispenser
•
SureShot Technical Assistance Center: 888 777-9990 or +1 902 865 9602
7
Sanitizing and Destaining
Sanitizing is required prior to first use and recommended monthly, as well as after the destaining
procedure.
Use appropriate Sanitizing solution or Destaining solution approved by your organization in the
following steps.
1. Ensure green LED indicator light is solid and not flashing.
2. Turn
off
power switch.
3. Open dispense faucet and drain any remaining product into an appropriately sized catch
container. Discard drained product.
a. Open dispense faucet by tilting lever into the lock position.
Lever can be tilted both directions.
Tilting
lever
fully
in one
direction
to
a horizontal position locks the faucet open.
Tilting lever in the opposite direction allows it to close automatically when released.
4. Flush with water.
a. With dispense faucet open and catch container in place under the faucet, pour 2 pots of hot
water (160°F
/
70°C) into top tank and allow it to flush through the system and drain out of
dispense faucet. Discard drained water.
Caution: Liquid will be hot!
5. Sanitize or Destain.
a. Close dispense faucet.
b. Pour 6 liters of sanitizing or destaining solution into top tank and let it run through the system
into the bottom tank.
6. When all the sanitizing or destaining solution has made its way to the bottom tank, open
dispense faucet and drain solution from bottom tank into an appropriately sized catch container.
7. Repeat step 5 and 6 re-using the solution previously drained.
8. When the sanitizing or destaining solution has gone through the heat exchanger 2 times, it can
be discarded.
9. If destaining, repeat steps 6-8 with sanitizer as well.
10. Remove two tanks and screen from the dispenser.
a. Grasp the dispense faucet of bottom tank and pull up over the two bumps, while sliding
straight out, just far enough to grasp sides of tank for complete removal. Set aside.
Do not
use dispense faucet to carry tank.
b. Remove top tank by sliding it out from the dispenser. Set aside.
c. Remove screen by pulling it up and out from the top tank.
11. Rinse with potable water.
12. Install screen into top tank, then load both tanks completely back into dispenser.
a. To install screen, set inside the top tank at the front. Ensure the tab is facing the front and is
attached to the front of the top tank.
b. When loading top tank, ensure it is pushed in all the way and the hole in the back of the top
tank aligns with the bulkhead fitting inside the back of the dispenser. See photo on the page 6.
Note:
Lid must close all the way. If lid does not close then the top tank is not fully installed.
c. To load bottom tank, lift and push back behind the two bumpers.
13. Flush with product.
The heat exchanger and lines contain water after sanitizing and destaining. This needs to be
flushed out with product prior to regular use.
a. With dispense faucet open, pour a half pot of product into top tank and allow to flush
through into an appropriately sized catch container for discarding.
14. Close dispense faucet.
15. Turn
on
power switch
16. To load product, see page 4.