Dual Check Valve Assembly Steps
Follow these steps to mount each check valve to the
steel bracket.
1.
Screw the
3/8”
MPT x
3/4”
HB tee or elbow into the
check valve using blue thread sealer. Orient the
hose barb to run the
3/4”
hose down the planter
toolbar.
2.
Insert the check valve into the
“
C
”
notch in the end
of the bracket, according to how you want the check
valve to be mounted on your planter. Orient the
wire clips up or to the side for easiest access.
3.
Slide the small
“
C
”
clamp bracket around the check
valve to lock it in place.
4.
Install the
1/4”
carriage bolt and flange nut to secure
the
“
C
”
clamp plate around the check valve.
5.
Now, mount the check valve on the bar. Hold the
check valve and long bracket assembly on the
toolbar. Slide the tab on the front of the short brack-
et into the upper or lower notch on the long bracket.
6.
Slide the L bolt into the appropriate slots on the
brackets for your tube size. Tighten the
1/4”
flange
nuts to hold the bracket in place.
Clamp
Bracket
400
-
1996A1 Dual Check Valve Mount Bracket
The long, short & clamp bracket come as one part con-
nected by break
-
off tabs.
Elbow at end of
section, Tee in
mid
-
locations.
Check Valve Mounting Options
The dual check valve mounting bracket is very flexible to fit many different planter configurations. Three
options are shown here to illustrate some of the possibilities.
Example 1. Use the long brack-
et on the top of a bar. The
check valve is mounted vertical-
ly. The liquid supply hose is ran
directly on the front side of the
bar. The U
-
bolt is placed in
slots to clamp on a 4x6 inch
tube.
Example 2. Use the long brack-
et on the rear of a bar. The
check valve is mounted over the
top of the bar. The supply line
would run above and behind the
bar. The short bracket is placed
in the
notch to
mount
the
check
valve
closer to
the bar.
Example 3. Use the long bracket on the
front of a 3x7 bar (vacuum tube on some
planters). Mount the check valve hang-
ing forward of the bar. The supply line
will run directly over the bar. The excess
bolt and
bracket
length
can be
cut off.
311
-
0408000800
-
05
1/4”
L Bolt
Short
Bracket
Long
Bracket
B
Components
Liquid
SureFire
Ag