14
P/N 974-
4135
Rev: 2.51
IX800 Operation & Service Manual
Maintenance
Warning:
Disconnect gas and electrical supplies before servicing.
Heater should be inspected before each use and at least annually by a qualified service person.
Weekly:
Gas Hose
Check for cracks and damaged connectors
Air flow
Remove any obstructions to air flow
Bearings
Lubricate bearings according to details below
Monthly
:
Cords and Connectors
Check for cracks, exposed wires, and dirt in electrical connectors
Physical Integrity
Check for damage to body, louvers, and inlet screens that may obstruct
air flow and impact combustion quality
Belts
Replace belt if cracked or worn according to details below.
Ensure belt tensioner is in place and tensioner roller is running smoothly.
Start of Season:
Combustion Chamber Remove burner assembly
Clean inside of combustion chamber with a wire brush. Vacuum all ash
and soot from combustion chamber.
Inspect combustion chamber for any damage. Do not use a heater that
has a hole in the combustion chamber.
Burner
Remove burner from burner assembly
Clean flame rod and igniter with solvent or emery cloth. Inspect for
cracked ceramic. Ensure they are properly centered in the burner
openings. Inspect wires for cracks or evidence of overheating
Ensure burner head screws are tight.
Ensure openings in orifice plate (located inside the burner pipe) are not
blocked. Ensure gasket and door seal are in place and not damaged.
Electrical components
Check all wiring for loose, cracked, or overheated wires and connectors.
Replace if necessary.
Ensure ground wires are properly connected.
Ensure control box seal is in place and not damaged.
Wipe dirt from motors. Motors have sealed bearings and do not require
lubrication.
VFD
If heater has not been used in more than a year, connect power, turn
power switch to the appropriate power source and let the heater sit for
one hour for each year since the heater was last used. This will reform
the capacitors and extend the life of the VFD.
Valve Train
Verify that manifold pressure matches the specification label. Adjust
regulator pressure if necessary.
Inspect strainer and clean if necessary.
Using soapy water or gas leak detector, check all gas connections for
leaks.
Impellers
Remove any dirt build-up on both burner and blower impellers.
Inspect impellers for loose or damaged fins.
Run heater and check for vibration.
Replace impellers that are damaged or causing vibration.
Body
Ensure all panels and shields are in place and that fasteners are tight.