Chapter 3: Advanced Chassis Setup
3-5
Figure 3-4. System Fan
3-5 Replacing the System Fan
The SC101S includes one 4-cm system fan that provides cooling for the chassis.
1. Power down the system as described in section 3-1 and remove the AC power
cord and the chassis cover.
2. Remove the failed fan power cable from motherboard.
3. Remove the screws securing the fan to the chassis wall and set these aside
for later use.
4. Lift the fan out of the chassis.
5. Align the replacement fan with the holes in the wall of the chassis.
6. Secure the fan to the chassis wall using the screws previously set aside.
7. Reconnect the fan cable to motherboard.
8. Reinstall the chassis top cover.
9. Reconnect the AC power cord and power up the system.