Chapter 5: Advanced Serverboard Setup
5-9
Installing a CPU Heatsink
Note:
in single and dual-CPU confi gurations, memory must be installed in the DIMM
slots associated with the installed CPU(s). Memory is limited to a maximum of 64
for single CPU and 128 GB for dual CPU confi gurations.
Use the following procedure for installing the
SNK-P0024AP4 active heatsink.
Installing the CPU Heatsink
Do not apply any thermal grease to
1.
the heatsink or the CPU die because
the required amount has already been
pre-applied.
Pre-attach the base plate and insulation
2.
slice under the serverboard.
Place the heatsink directly on top of the
3.
CPU so that the fan faces the front of
the chassis and the mounting holes are
aligned with those on the base plate.
Screw in the two screws slightly.
4.
Tighten each screw a few turns at a
5.
time while alternating between the two
until fully tightened.
Connect the fan cable to the
6.
serverboard CPU fan header.