8017R-TF+

8017R-7FT+

®

USER’S MANUAL

Revision 1.0

Содержание SUPERSERVER 8017R-7FT+

Страница 1: ...SUPER SUPERSERVER 8017R TF 8017R 7FT USER S MANUAL Revision 1 0...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...and the SC818A 1K43LPB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 8017R TF 8017R 7FT into a rack and check out the server configuratio...

Страница 4: ...serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC818A 1K43LPB 1U rackmount server chassis You should follow the procedures given in this chapter when...

Страница 5: ...v Preface Notes...

Страница 6: ...ng Supermicro 1 5 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack...

Страница 7: ...Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 2 5 2 Connecting Cables 5 2 Connecting Data Cables 5 2 Connecting Power Cables 5 2 Connecting the Cont...

Страница 8: ...l 6 5 Accessing the Drive Bays 6 6 SATA Drive Installation 6 7 Mounting a Drive in a Drive Carrier 6 7 Installing removing SATA Drives 6 8 SATA Backplane 6 8 DVD ROM and Floppy Drive Installation Opti...

Страница 9: ...the serverboard and chassis various hardware components have been included with the SuperServer 8017R TF 8017R 7FT as listed below Seven 4 cm hot swap chassis fans FAN 0101L4 One air shroud MCP 310 8...

Страница 10: ...800 memory Modules of the same size and speed should be used See Chapter 5 details SAS An LSI 2208 controller is included on the X9QR7 TF to provide an eight port SAS 3 0 subsystem which is RAID 0 1 5...

Страница 11: ...MM 1066 1333 1600 DDR3 DMM DDR3 1066 1333 1600 CHA DDR3 1066 1333 1600 CHB DDR3 1066 1333 1600 CHC DDR3 1066 1333 1600 CHD 1066 1333 1600 DDR3 DMM 1066 1333 1600 DDR3 DMM 1066 1333 1600 DDR3 DMM 1066...

Страница 12: ...erServer 8017R TF 8017R 7FT provides you with system monitoring and control LEDs indicate system power HDD activity network activity system overheat and power supply failure A main power button and a...

Страница 13: ...Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro n...

Страница 14: ...1 6 SUPERSERVER 8017R TF 8017R 7FT User s Manual Notes...

Страница 15: ...any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 8017R TF 8017R 7FT It sho...

Страница 16: ...rmine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible...

Страница 17: ...quipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condi...

Страница 18: ...that came with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit Each assembly consists of two sections...

Страница 19: ...the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws Repeat these steps for the left outer rail See Figure 2 2 Locking Tabs...

Страница 20: ...to the rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depr...

Страница 21: ...s others on the drive car riers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components There are also two buttons on the chassis...

Страница 22: ...fan failure When on continuously on and not flashing it indicates an overheat condition which may be caused by cables ob structing the airflow in the system or the ambient room temperature being too w...

Страница 23: ...en that particular drive is being accessed Please refer to Chapter 6 for instructions on replacing failed drives Red The red LED to indicate a drive failure If one of the drives fail you should be not...

Страница 24: ...3 4 SUPERSERVER 8017R TF 8017R 7FT User s Manual Notes...

Страница 25: ...ng power you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circu...

Страница 26: ...jects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard...

Страница 27: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 28: ...this practice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged ba...

Страница 29: ...ully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect you...

Страница 30: ...the pin 1 locations The following data cables with their locations noted should be connected See the layout on page 5 9 for connector locations SATA drive data cables I SATA0 2 Control Panel cable JF1...

Страница 31: ...ure 5 2 I O Ports I O Ports 1 COM Port 6 USB3 Port 2 USB0 Port 7 LAN Port 1 3 USB1 Port 8 LAN Port 2 4 Dedicated IPMI LAN Port 9 VGA Port 5 USB2 Port 10 UID Switch 1 6 9 1 7 8 4 3 5 2 Power Button Blu...

Страница 32: ...fore you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise c...

Страница 33: ...ARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned caref...

Страница 34: ...that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled Close...

Страница 35: ...Heatsink Bracket under neath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the CPU 4 Finish the installation by f...

Страница 36: ...ng with P1 DIMM A1 The release tabs on the slot should be pushed outward 2 Insert each DIMM module vertically into its slot Pay attention to the notch along the bottom of the module to avoid installin...

Страница 37: ...MMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 Any memory pairs in P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 slots 2 CPUs 4 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF1 2 CPUs 6 DIMMs CPU1...

Страница 38: ...emory List posted on our website at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 4600 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width...

Страница 39: ...anks Per DIMM Data Width See the Note Below Memory Capacity Per DIMM Speed MT s and Voltage Validated by Slot per Channel SPC and DIMM Per Channel DPC 1 Slot Per Channel 2 Slots Per Channel 1DPC 1DPC...

Страница 40: ...MMP1 P4 DIMMN2 P4 DIMMN1 P3 DIMMK1 P3 DIMMJ2 P3 DIMMJ1 P3 DIMMM2 P3 DIMML1 P3 DIMML2 P3 DIMMM1 P2 DIMME1 P2 DIMME2 P2 DIMMF1 P2 DIMMG2 P2 DIMMG1 P2 DIMMH2 P2 DIMMH1 P1 DIMMD2 P1 DIMMD1 P1 DIMMC2 P1 DI...

Страница 41: ...JIPMB1 4 pin External BMC I2 C Header for an IPMI Card JD1 Speaker Power LED Indicator JF1 Front Panel Control Header JL1 Chassis Intrusion Header JOH1 Overheat LED Indicator JPI2 C1 Power Supply SMB...

Страница 42: ...4 Ground 5 8 12V ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_...

Страница 43: ...for pin definitions NIC2 LED Pin Definitions JF1 Pin Definition 9 Activity 10 Link HDD LED Pin Definitions JF1 Pin Definition 13 3 3V 14 HD Active NIC2 JLAN2 LED The LED connections for JLAN2 are on...

Страница 44: ...the right for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWM Control Power On LED The Po...

Страница 45: ...nect an LED to provide warning of chassis overheating This LED will blink to in dicate a fan failure Refer to the table on right for pin definitions Overheat LED Pin Definitions Pin Definition 1 5vDC...

Страница 46: ...ch and two LED indicators are provided on the serverboard The UID Switch is located next to the LAN ports on the I O backplane The rear UID LED is located next to the UID switch The Front Panel UID LE...

Страница 47: ...hip also provides USB connection for front access cables are not included See the tables on the right for pin definitions Backplane Accessible USB Connectors Pin Definitions USB 0 2 Pin Definition USB...

Страница 48: ...ny passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s It is al...

Страница 49: ...the application that hangs See the table on the right for jumper settings Watch Dog must also be enabled in BIOS Note When enabled the user needs to write their own application software in order to d...

Страница 50: ...nection See the table at right for more information IPMI LAN LEDs LED Color State Definition Left Green Solid 100 Mb s Right Amber Blinking Activity BMC Heartbeat LED A BMC Heartbeat LED is located at...

Страница 51: ...le on the right for pin definitions SAS Ports X9QR7 TF only There are no jumpers to configure the onboard SAS ports These ports are supported by the Intel chipset See the table on the right for pin de...

Страница 52: ...ckaged with your motherboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right o...

Страница 53: ...ial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoc...

Страница 54: ...nloaded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we w...

Страница 55: ...vent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a...

Страница 56: ...both connectors Pull all excess cabling out of the airflow path The control panel LEDs inform you of system status See Chapter 3 System In terface for details on the LEDs and the control panel buttons...

Страница 57: ...the top cover 5 Push the cover away from you toward the rear of the chassis until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server 6 To comple...

Страница 58: ...with the same type and model the system can continue to run with a failed fan 1 Remove the top chassis cover while the system is still running to determine which of the fans has failed Then turn off t...

Страница 59: ...t to gain access to the drive bays 1 To remove the bezel first unlock the front of the chassis then press the release knob see Figure 6 4 2 Carefully remove the bezel with both hands A filter located...

Страница 60: ...ructions DVD ROM Floppy Disk Drives For installing removing a DVD ROM or floppy disk drive you will need to gain access to the inside of the 8017R TF 8017R 7FT by removing the top cover of the chassis...

Страница 61: ...elp promote proper airflow for the drive bays For this reason even empty carriers without drives installed must remain in the chassis To add a new drive install a drive into the carrier with the print...

Страница 62: ...operating system you use must have RAID support to enable the hot swap capability of the drives The backplane is already preconfigured so there are no jumpers or switches present on it Installing rem...

Страница 63: ...inside of the server With the chassis cover removed unplug the power and data cables from the drive you want to remove Then locate the locking tab at the rear of the drive It will be on the left side...

Страница 64: ...ntact information in the Preface As there is only one power supply unit in the 8017R TF 8017R 7FT power must be completely removed from the server before removing and replacing the power supply unit f...

Страница 65: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 7 Removing Replacing the Power Supply Note the serverboard shown may or may not be the same as in your system...

Страница 66: ...6 12 SUPERSERVER 8017R TF 8017R 7FT User s Manual Notes...

Страница 67: ...e configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for informational te...

Страница 68: ...tility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Caution Do not upgra...

Страница 69: ...d 10 12 2012 System Time This item displays the system time in HH MM SS format e g 15 32 52 Supermicro X9QR7 TF Version This item displays the SMC version of the BIOS ROM used in this system Build Dat...

Страница 70: ...nstead of the normal POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn RO...

Страница 71: ...off immediately as soon as the user presses the power button If this feature is set to 4 Seconds Override the system will power off when the user presses the power button for 4 seconds or longer The...

Страница 72: ...supported by the CPU installed in the Socket selected Clock Spread Spectrum Select Enable to enable Clock Spectrum support which will allow the BIOS to moni tor and attempt to reduce the level of Ele...

Страница 73: ...use the Intel Advanced Encryption Standard AES New Instruc tions NI to ensure data security The options are Enabled and Disabled MLC Streamer Prefetcher Available when supported by the CPU If set to...

Страница 74: ...ustom If the option is set to Custom the following items will display EIST Available when Power Technology is set to Custom EIST Enhanced Intel SpeedStep Technology allows the system to au tomatically...

Страница 75: ...hen Power Technology is set to Custom This feature allows the user to set the limit on the C State package register The options are C0 C2 C6 and No Limit Energy Performance Bias This setting allows th...

Страница 76: ...s This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enabled and Dis...

Страница 77: ...ort for Slot 2 Select GEN3 to enable PCI Exp Generation 3 support for Slot 2 The options are GEN1 GEN2 and GEN3 CPU 1 PCIe Slot 3 Link Width This feature allows the user to set the PCI Exp bus speed b...

Страница 78: ...speed for QPI Link connections The options are Fast and Slow QPI Link Frequency Select Use this feature to select the desired QPI frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s DIMM Con...

Страница 79: ...se this feature to force a DDR3 memory module to run at a frequency other than what is specified by the manufacturer The options are Auto Force DDR3 800 Force DDR3 1066 Force DDR3 1333 Force DDR3 1600...

Страница 80: ...ottling Throttling improves reliability and reduces power consumption in the proces sor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal...

Страница 81: ...CI hand off When enabled EHCI ownership change will be claimed by the EHCI driver The options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically detec...

Страница 82: ...simultaneously The options are Enabled and Disabled RAID Mode The following items are displayed when RAID Mode is selected Port 0 5 Hot Plug Select Enabled to enable hot plug support for the particula...

Страница 83: ...This feature allows the user to set the Active State Power Management ASPM level for a PCI E device Select Force L0s to force all PCI E links to operate at L0s state Select Auto to allow the system BI...

Страница 84: ...et to Enabled Set this item to Enabled to activate IPv6 PXE Support The options are Enabled and Disabled Super IO Configuration Super IO Chip This item displays the Super IO chip used in the motherboa...

Страница 85: ...te for serial port 2 The options are SOL Serial On LAN and COM Serial Port Console Redirection COM 1 COM 2 These two submenus allow the user to configure the following Console Redirection settings for...

Страница 86: ...None if you do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity...

Страница 87: ...onsole Redirection Select Enabled to use a COM Port selected by the user for Console Redirection The options are Enabled and Disabled Console Redirection Settings This feature allows the user to speci...

Страница 88: ...Use this feature to select the ACPI State when the system is in sleep mode Select S1 CPU Stop Clock to erase all CPU caches and stop executing instructions Power to the CPU s and RAM is maintained but...

Страница 89: ...e Take Ownership and TPM Clear Note During restart the computer will reboot in order to execute the pend ing operation and change the state of the security device Current Status Information This item...

Страница 90: ...at need to be enabled for the Intel Trusted Execution Technology to work properly in the system VT d Support Intel Virtualization Technology with Direct I O support VT Support Intel Virtualization Tec...

Страница 91: ...nagement BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled M...

Страница 92: ...to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default...

Страница 93: ...led in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Sele...

Страница 94: ...ny changes the user made to the IPMI settings will be applied at the next system boot Configuration Address Source This feature allows the user to select the source of the IP address for this computer...

Страница 95: ...This submenu allows the user to configure the following boot settings for the system Boot Option Priorities Boot Option 1 Boot Option 2 Boot Option 3 etc Use this feature to specify the sequence of b...

Страница 96: ...Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long...

Страница 97: ...nd Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select Sa...

Страница 98: ...lts Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to save the c...

Страница 99: ...er for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error...

Страница 100: ...A 2 SUPERSERVER 8017R TF 8017R 7FT User s Manual Notes...

Страница 101: ...p to 1 TB of ECC LRDIMM or ECC non ECC UDIMM DDR3 1600 1333 1066 800 memory Note See the memory section in Chapter 5 for details SAS Controller 8017R 7FT only LSI 2208 controller for eight SAS ports R...

Страница 102: ...requency 50 to 60 Hz Power Supply Rated Output Power 1400W Part PWS 1K43F 1R Rated Output Voltages 12V 100A 115Vac 117A 243Vac 5Vsb 6A Operating Environment Operating Temperature 10 to 35 C 50 to 95 F...

Страница 103: ...B 3 Appendix B System Specifications Notes...

Страница 104: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell su...