5-6
S
UPER
S
ERVER 6015TC-LFT User's Manual
Socket key
CPU installed in socket
PnP cap released
from load plate
3. Use your thumb and your index fi nger
to hold the CPU at opposite sides.
4. Align pin1 of the CPU (the corner
marked with a triangle) with the notched
corner of the CPU socket.
5. Find the corner of the CPU that
has a semi-circle cutout below a gold
dot (CPU key). This corner should be
aligned with the cutout on the socket
(socket key).
6. Once aligned, carefully lower the
CPU straight down into the socket. Do
not drop the CPU on the socket, do not
move the CPU horizontally or vertically
and do not rub the CPU against any sur-
face or any of the contacts, which may
damage the CPU and/or contacts.
7. With the CPU in the socket, inspect
the four corners of the CPU to make
sure that it is properly installed.
8. Use your thumb to gently push the
load lever down until it snaps into the
retention clasp.
9. If the CPU is properly installed into
the socket, the PnP cap will be auto-
matically released from the load plate
when the lever locks. Remove the cap.
Repeat steps to install a second CPU
if desired.
Warning!
Keep the plastic PnP cap.
The serverboard must be shipped with
the PnP cap properly installed to protect
the CPU socket. Shipment without the
PnP cap properly installed will void the
warranty.
CPU key
CPU pin 1
Notched corner
Gold dot
Load lever
Содержание SUPERSERVER 6015TC-LFT
Страница 1: ...SUPER SUPERSERVER 6015TC LFT USER S MANUAL Revision 1 0...
Страница 5: ...v Preface Notes...
Страница 16: ...1 8 SUPERSERVER 6015TC LFT User s Manual Notes...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...
Страница 26: ...2 10 SUPERSERVER 6015TC LFT User s Manual Notes...
Страница 30: ...3 4 SUPERSERVER 6015TC LFT User s Manual Notes...
Страница 58: ...5 24 SUPERSERVER 6015TC LFT User s Manual Notes...
Страница 90: ...A 2 SUPERSERVER 6015TC LFT User s Manual Notes...
Страница 95: ...C 3 Appendix C System Specifications Notes...