B-2
S
UPER
S
ERVER 5017R-WRF User's Manual
Weight
Gross (Bare Bone): 43 lbs. (19.5 kg.)
System Cooling
Four 4-cm heavy-duty counter-rotating fans
System Input Requirements
AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 6.1A - 2.6A
Rated Input Frequency: 50 to 60 Hz
Power
Supply
Rated Output Power: 500W (Part# PWS-501P-1R)
Rated Output Voltages: +12V (41.7A), +5Vsb (4A)
Operating
Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3,
CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate”
Содержание SUPERSERVER 5017R-WRF
Страница 1: ...SUPERSERVER 5017R WRF SUPER USER S MANUAL 1 0...
Страница 5: ...Notes Preface v...
Страница 14: ...1 6 SUPERSERVER 5017R WRF User s Manual Notes...
Страница 22: ...2 8 SUPERSERVER 5017R WRF User s Manual Notes...
Страница 60: ...5 30 SUPERSERVER 5017R WRF User s Manual Notes...
Страница 70: ...6 10 SUPERSERVER 5017R WRF User s Manual Figure 6 6 Removing Replacing the Power Supply...
Страница 108: ...A 2 SUPERSERVER 5017R WRF User s Manual Notes...
Страница 111: ...B 3 Appendix B System Specifications Notes...