B-2
S
UPER
S
ERVER 1028U Series User's Manual
Serverboard
X10DRU-i+ (proprietary form factor)
Dimensions: 19.7" x 9.2" (500.4 x 233.7 mm)
Chassis
SC119UAC-R750 or SC119UAC2-R750 (NVMe);1U rackmount
Dimensions: (WxHxD) 17.2 x 1.7 x 27.8 in. (437 x 43 x 706 mm)
System Cooling
Four to eight sets of 4-cm counter-rotating cooling fans (fan speed controlled by
IPMI)
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 9.5-4.5 Amps
Rated Input Frequency: 50-60 Hz
Power Supply
80-plus Platinum AC-DC, (Part# PWS-750P)
Rated Output Power: 750W
Rated Output Voltages: +12V, +12Vsb (2A)
Operating Environment
Operating Temperature: 10ºC to 35ºC (50ºF to 95ºF)
Expanded Operating Temperature: 5°C to 40°C (41°F to 104°F) *
1, 2
Non-Operating Temperature: -40ºC to 60ºC (-40ºF to 140ºF)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-Operating Relative Humidity: 5% to 95% (non-condensing)
*Conditions for 35-40ºC Operating Temperature
•
Change heatsinks to part SNK-P0057PSU.
•
Install eight cooling fans.
•
GPU is not supported.
Note 1
: When operating in the expanded temperature range, system performance
is equivalent to the normal operating temperature range.
Содержание SUPERSERVER 1028U Series
Страница 1: ...SUPER USER S MANUAL Revision 1 0a SUPERSERVER 1028U Series...
Страница 12: ...1 6 SUPERSERVER 1028U Series User s Manual Notes...
Страница 22: ...2 10 SUPERSERVER 1028U Series User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 1028U Series User s Manual Notes...
Страница 82: ...6 12 SUPERSERVER 1028U Series Series User s Manual Notes...
Страница 116: ...A 2 SUPERSERVER 1028U Series User s Manual Notes...
Страница 120: ...B 4 SUPERSERVER 1028U Series User s Manual Notes...