SC847 Chassis Manual
6-8
Note
: Figures are for illustrative purposes only. Servers should always be installed
in racks from the bottom up.
Installing the Chassis into a Rack
1.
Confirm that the inner rails are properly installed on the chassis.
2.
Confirm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
Figure 6-6: Installing into a Rack
Ball-Bearing
Shuttle
Standard Chassis Installation
Stability hazard
. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.