background image

SUPERSERVER

®

8028B-TR3F

8028B-C0R3FT

USER’S MANUAL

Revision 1.0a

Содержание SuperServer 8028B-C0R3FT

Страница 1: ...SUPERSERVER 8028B TR3F 8028B C0R3FT USER S MANUAL Revision 1 0a...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...main components included with the server system and describes the main features of the X10QBL CT serverboard and the SC828TS R1K43LPB chassis Chapter 2 Server Installation This chapter describes the...

Страница 4: ...d Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC828TS R1K43LPB server chassis You should follow the procedures given in this chapter when installing removing or...

Страница 5: ...Notes Preface v...

Страница 6: ...4 I O 1 4 Cooling System 1 4 1 4 Advanced Power Management 1 5 Intel Intelligent Power Node Manager NM 1 5 Manageability Engine ME 1 5 1 5 Contacting Supermicro 1 6 Chapter 2 Server Installation 2 1 O...

Страница 7: ...3 2 Power LED 3 2 Universal Information LED 3 2 HDD LED 3 2 NIC2 LED 3 3 NIC1 LED 3 3 Power Fail LED 3 3 3 4 Drive Carrier LEDs 3 3 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About S...

Страница 8: ...g the Heatsink 5 10 5 5 Installing Memory 5 11 Memory Support 5 11 Processor Memory Module Population Configuration 5 12 Fully Populated Configuration 5 12 Half Populated Configuration 5 12 Populating...

Страница 9: ...ving the Hard Drive Tray and Installing a Hard Drive 6 8 6 8 Power Supply 6 10 Removing the Power Supply 6 10 Installing the Power Supply 6 12 Chapter 7 BIOS 7 1 Introduction 7 1 Starting the Setup Ut...

Страница 10: ...SUPERSERVER 8028B TR3F C0R3FT User s Manual x Notes...

Страница 11: ...ve trays MCP 220 00075 0B One 1 Round 30AWG 30 76 cm 16 pin to 16 pin ribbon cable CBL 0071L SuperServer 8028B C0R3FT only Two 2 Mini SAS HD to 4 SATA w 75 cm SB cable CBL SAST 0556 SuperServer 8028B...

Страница 12: ...IMM ECC DDR3 1600 1333 1066 MHz speed SDRAM in a two channel memory bus Memory sizes of 4GB 8GB 16GB 32GB and 64GB size 1 35V 1 5V voltages are supported Please refer to Chapter 5 for installing memor...

Страница 13: ...Interface 2 0 support AC power loss recovery Wake on Ring WOR Wake on LAN WOL support Main switch override mechanism Intel Intelligent Power Node Manager 3 0 CPU Thermal Trip support Fan status monit...

Страница 14: ...ty network activity system overheat and power supply failure A main power button and a system reset button are also included I O The SC828TS R1K43LPB is an quad optimized chassis designed to be used i...

Страница 15: ...mory Buffer CTRL X10QBL CT only X10QBL CT X10QBL i350 Memory Buffer CTRL PCIE PHY PHY PCIE X8 1 4 Advanced Power Management Intel Intelligent Power Node Manager NM The Intel Intelligent Power Node Man...

Страница 16: ...o com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support...

Страница 17: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 8028B T...

Страница 18: ...installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the ra...

Страница 19: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Страница 20: ...e with the rack unit you are using Note This rail will fit a rack between 26 8 and 36 4 deep Warning Do not pick up the server with the front handles They are designed to pull the system from a rack o...

Страница 21: ...his Side Faces Outward Locking Tab Middle Rail Outer Rail Locking Tabs Each inner rail has a locking tab This tab locks the chassis into place when installed and pushed fully into the rack These tabs...

Страница 22: ...the Outer Rails Figure 2 2 1 Identify the left and right outer rail assemblies as described on page 2 4 2 Pull the inner rail out of the outer rail until it is fully extended as illustrated below 3 Pr...

Страница 23: ...assis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position which secures the inner rail to the chassis 4 Secur...

Страница 24: ...he rack If necessary use screws to secure the outer rails to the rack as illustrated above 4 Pull out the rear of the outer rail adjusting the length until it fits within the posts of the rack 5 Hang...

Страница 25: ...ont of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides until the locking tab of the inner rail clicks into the front of the middle...

Страница 26: ...he chassis onto a rack Installing the Chassis into a Rack 1 Install the whole rail assembly onto the rack as described on page 5 7 2 Release the inner rail without retracting the middle rail 3 Install...

Страница 27: ...Panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off button Power The main power switch is used to apply or remove power from the...

Страница 28: ...his indicates the IDE channel activity It also indicates SAS SATA drive SCSI drive and or DVD ROM drive activity when flashing Universal Information LED See the following table for the status shown by...

Страница 29: ...ATA drives Each drive carrier displays two status LEDs on the front of the carrier LED Color State Status Activity LED Green Solid On SAS drive installed Green Blinking I O activity Status LED Red Sol...

Страница 30: ...SUPERSERVER 8028B TR3F C0R3FT User s Manual 3 4 Notes...

Страница 31: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 32: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 33: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 34: ...chlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de bra...

Страница 35: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 36: ...d the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbe...

Страница 37: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 38: ...Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar...

Страница 39: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 40: ...e same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met e...

Страница 41: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 42: ...ustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por com...

Страница 43: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 44: ...Die Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzich...

Страница 45: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 46: ...yclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still...

Страница 47: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 48: ...UL CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann z...

Страница 49: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 50: ...kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of...

Страница 51: ...ng keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a gr...

Страница 52: ...e layout on page 5 9 for connector locations Important Make sure the the cables do not come into contact with the fans Connecting Power Cables The X10QBL CT serverboard has a 24 pin primary power supp...

Страница 53: ...Control Panel Header Pins Power Button OH Fan Fail PWR Fail LED 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3 3 V UID Switch UID LED Ground Ground 19 20 3 3V X Ground NMI...

Страница 54: ...ts I O Ports 1 COM Port 2 Back Panel Vertical USB 2 0 Port 2 3 VGA Blue 4 Back Panel USB 2 0 Port 1 5 Back Panel USB 2 0 Port 0 6 IPMI_LAN 7 Gigabit_LAN 1 see note below 8 Gigabit_LAN 2 see note below...

Страница 55: ...nly 3 Make sure to install the motherboard into the chassis before you install the CPU heatsink 4 When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket c...

Страница 56: ...from its locking position 1 OPEN1st Press down on the Load Lever labeled Close 1st 2 Pull the lever away from the socket OPEN1st 2 Gently push down to pop the load plate open OPEN1st 1 3 With the lev...

Страница 57: ...cket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket W...

Страница 58: ...Lever Lock Lever Lock Push down and lock the lever labeled Open 1st Push down and lock the lever labeled Close 1st Gently close the load plate 1 2 3 4 OPEN1st OPEN1st 8 Close the load plate with the C...

Страница 59: ...heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws unt...

Страница 60: ...gle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is loosened remove the CPU from the CPU socket 4 Remove the used thermal grease and cle...

Страница 61: ...CPU2 CPU3 CPU4 be installed Using three CPUs is not recommended Please install your DIMM modules according to the number of CPUs used in the system 2 To optimize memory performance please install 16...

Страница 62: ...D1 P1M1 DIMMA2 B2 P1M1 DIMMC2 D2 CPU2 P2M1 P2M1 DIMMA1 B1 P2M1 DIMMC1 D1 P2M1 DIMMA2 B2 P2M1 DIMMC2 D2 CPU3 P3M1 P3M1 DIMMA1 B1 P3M1 DIMMC1 D1 P3M1 DIMMA2 B2 P3M1 DIMMC2 D2 CPU4 P4M1 P4M1 DIMMA1 B1 P...

Страница 63: ...http www supermicro com support resources mem cfm RDIMM LRDIMM DDR3 ECC in Lockstep Mode 1 1 Type Ranks Per DIMM Data Width Memory DIMM Capacity GB See the Note Below Max Speed Ghz Voltage V Slots per...

Страница 64: ...date four PCI low profile expansion card slots that are available in the rear of the chassis for two 2 PCI E 3 0 x16 slots CPU1 Slot1 CPU2 Slot3 and two 2 PCI E 3 0 x8 slots CPU2 Slot2 CPU2 Slot4 of t...

Страница 65: ...PWR5 JPWR4 JPWR1 JL1 JPSAS1 JI2C2 J17 LED1 P3M1 DIMMA2 P2M1 DIMMD2 P2M1 DIMMC2 P1M1 DIMMA1 P1M1 DIMMB1 P1M1 DIMMC1 P1M1 DIMMD1 P2M1 DIMMA1 P2M1 DIMMC1 P2M1 DIMMD1 P3M1 DIMMB1 P3M1 DIMMC1 P3M1 DIMMD1 P...

Страница 66: ...QBL CT Pins 1 2 Enabled JPT1 Trusted Platform Module TPM Enable Pins 1 2 Enabled JPME2 Manufacture Mode ME Select Pins 1 2 Normal JPS1 SAS Enable For X10QBL CT Pins 1 2 Enabled JWD1 Watch Dog Timer En...

Страница 67: ...or X10QBL CT 10G LAN TLAN ports 1 2 supported by Intel X540 LAN controller IPMI_LAN Gigabit IPMI dedicated LAN on the I O back panel supported by the BMC for IPMI use L SAS0 3 L SAS4 7 for X10QBL CT S...

Страница 68: ...21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Power Button Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Processor Power Connector The Reset Button connection is located on pins 3 and 4...

Страница 69: ...s OH Fan Fail PWR Fail Blue_ UID LED Pin Definitions JF1 Pin Definition 7 Blue_UID LED 8 OH Fan Fail Power Fail OH Fan Fail PWR Fail LED Status Red LED State Definition Off Normal On Overheat Flashing...

Страница 70: ...for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWM Modulation HDD UID LED The HDD LED co...

Страница 71: ...I O back panel Two internal USB headers located next to the I SATA ports 4 5 provide four USB 2 0 connections USB 4 5 6 7 for front access In addition a Type A USB header located close to the 24 pin m...

Страница 72: ...to turn off the LED indicator The UID Indicators provide easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI on the motherboard For more inform...

Страница 73: ...bles on the right for pin definitions PWR LED Connector Pin Definitions Pin Setting Definition Pin 1 JD1_PIN1 Pin2 FP_PWR_LED Pin3 FP_PWR_LED Speaker Connector Pin Settings Pin Setting Definition Pin...

Страница 74: ...3 Ground 4 Data 5 Load 6 Ground 7 Clock 8 NC NC No Connection Power SMB Pin Definitions Pin Definition 1 Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V Power SMB I2 C Connector Power System Management Bus I...

Страница 75: ...the system remove the AC power cord and then short JBT1 to clear CMOS Note 2 Be sure to remove the onboard CMOS Battery before you short JBT1 to clear CMOS Note 3 Clearing CMOS will also clear all pas...

Страница 76: ...See the table on the right for jumper settings LAN Enable Disable JPL1 enables or disables Gigabit_LAN ports on the X10QBL CT while JPTG1 enables or disables 10G LAN ports on the X10QBL T See the tab...

Страница 77: ...rt to enhance data integrity and system security See the table on the right for jumper settings The default setting is enabled TPM Enable Jumper Settings Jumper Setting Definition Pin 1 2 Enabled Defa...

Страница 78: ...LAN Connection Speed Indicator Left LED Settings LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz 10G LAN Link LEDs LED Settings for X10QBL CT LED Color Definition Off No Connection 10 or 100...

Страница 79: ...removing or installing components See the tables at right for more information Onboard PWR LED Indicator LED States LED Color Definition Off System Off PWR cable not connected Green System On SAS Hear...

Страница 80: ...support SATA 3 0 connections while I SATA ports 2 5 support SATA 2 0 These SATA connectors provide serial link connections which are faster than Parallel ATA connections SAS 3 0 Ports for X10QBL CT on...

Страница 81: ...Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at http...

Страница 82: ...s monitoring program that functions in a command line or web based interface in Windows and Linux operating systems The program monitors system health information such as CPU temperature system voltag...

Страница 83: ...5 Interface Display Screen Remote Control Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm For Linux...

Страница 84: ...facturer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 8 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully D...

Страница 85: ...m very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded...

Страница 86: ...form you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 6 3 Removing the Chassis Cover Before installing any components r...

Страница 87: ...Chapter 6 Advanced Chassis Setup 6 3 1 3 1 4 1 3 1 2 1 2 Figure 6 2 Removing the Chassis Cover Figure 6 3 Lifting the Chassis Cover 1 5 4 Slide the cover back 5 Lift the cover upwards...

Страница 88: ...hassis fans is a simple procedure Removing a Chassis Fan Figure 6 4 1 If necessary open the chassis cover while the power is running to determine which fan has failed Never run the server for an exten...

Страница 89: ...ouch the backplane or obstruct the holes which aid in proper airflow Installing a Chassis Fan Figure 6 5 6 Slide the fan housing into the chassis fan mounting bracket 7 Push down gently on the top of...

Страница 90: ...ned to accomodate a variety of motherboards Some motherboard and heatsink combinations will require portions of the air shroud to be bent or removed to fit Installing and Adjusting the Air Shroud Figu...

Страница 91: ...d open the chassis cover 3 Remove the screw holding the slot cover in place for each slot you want to populate Keep this screw for later use 4 Connect the expansion cards to the motherboard Follow the...

Страница 92: ...disk drive into the chassis it is necessary to remove the HDD carrier from the chassis Removing a Hard Drive Carrier 1 Press the release tab on the front of each hard drive try to unlock the HDD carr...

Страница 93: ...ews that attach to the both sides of the dummy HDD 2 Slide out the dummy HDD as shown Figure 6 9 Removing the Dummy Hard Drive 3 Slide a hard drive into the HDD carrier 4 Secure the HDD to the carrier...

Страница 94: ...the Supermicro Web site at http www supermicro com products nfo files storage SAS CompList pdf 6 8 Power Supply The SC828 chassis has two 1400 Watt power supply This power supply is auto switching ca...

Страница 95: ...dvanced Chassis Setup 6 11 Figure 6 12 Releasing the Power Supply Release Button Handle 1 2 1 3 4 Gently pull the power supply forward and out of the chassis Figure 6 13 Figure 6 13 Removing the Power...

Страница 96: ...upply Installation 1 Unplug all power leading to the chassis 2 Insert the power supply into its slot in the front of the chassis gently pushing it back into the chassis until it clicks into position F...

Страница 97: ...screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an ar...

Страница 98: ...System Date System Time Use this option to change the system date and time using the arrow keys Enter new values through the keyboard and press Enter Press the Tab key to move between fields The date...

Страница 99: ...ions Select the Advanced tab to access the following submenu items Boot Features Boot Configuration Quiet Boot Use this item to select bootup screen display between POST messages and the OEM logo Sele...

Страница 100: ...d to the host adaptor to function as the bootable disk If this item is set to Postponed the BIOS ROM of the host adaptors will only capture Interrupt 19 during bootup from a legacy device The options...

Страница 101: ...State CPU Configuration This submenu displays the following CPU information as detected by the BIOS It also allows the user to configure CPU settings Processor 0 Processor 1 This submenu displays the...

Страница 102: ...tack This feature is used in conjunction with the items Clear MCA VMX Enable SMX and Lock Chipset for Virtualization media support The default setting is Enable Refer to Intel and Microsoft websites f...

Страница 103: ...Direct Cache Access DCA Select Enable to use Intel DCA Direct Cache Access Technology to improve the efficiency of data transferring and accessing The options are Enable and Disable AES NI New Encryp...

Страница 104: ...tem Select SW_ANY to change the P State coordination type for a software program in the system The options are HW_All SW_ALL and SW_ANY CPU C State Control Package C State limit This feature allows th...

Страница 105: ...power consumption The options are Enable and Disable CPU Advanced PM Turning Energy Perf BIAS Energy Perf BIAS Energy Performance Tuning Use this feature to select whether the BIOS of operating system...

Страница 106: ...de a processor will always remain clear during electric tuning The options are Disable and Enable IIO0 Configuration CPU1 SLOT1 PCI E 3 0 X16 Use the items below to configure the PCI E settings for a...

Страница 107: ...he PCI E port specified by the user The options are GEN1 2 5 GT s GEN2 5 GT s GEN3 8 GT s and Auto L SAS0 3 JSAS1 L SAS4 7 JASA2 Use the items below to configure the PCI E settings for a PCI E port sp...

Страница 108: ...cted I O VT d Intel VT for Direct I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine M...

Страница 109: ...data transfer speed for QPI Link connections The default setting is Fast Link Frequency Select Use this feature to select the desired frequency for QPI Link connections The options are 6 4GB s 7 2GB...

Страница 110: ...ory Controller IMC information DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specified in the specification The options are Auto 1067 1333 1600 1867...

Страница 111: ...he early stage of POST Power On Self Test The options are is Enable and Disable Command 2 Data Tuning Select Enabled to fine tune electrical command paths from the host system to the memory extension...

Страница 112: ...by the motherboard Memory mirroring creates a duplicate copy of the data stored in the memory to enhance data security Sparing This item indicates if memory sparing is supported by the motherboard Me...

Страница 113: ...rleaving Use this feature to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correct...

Страница 114: ...uth Bridge settings USB Configuration The following USB items will display USB Module Version USB Devices Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support lega...

Страница 115: ...chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enabled and Disabled Configure SATA as S...

Страница 116: ...0 to 1 set this item to allow the PCH to initialize the device The options are Enabled and Disabled SATA Thermal Throttling Timing Available for SATA Port 0 Port 1 only Use this item to configure the...

Страница 117: ...bled SATA Thermal Throttling Timing Available for SATA Port 0 Port 1 only Use this item to configure the interactive settings for thermal throttling The options are Solid State Drive Hard Disk Drive a...

Страница 118: ...to operate at L0s state Select Auto to allow the system BIOS to automatically set the ASPM level for the system Select Disabled to disable ASPM support The options are Disabled Force L0s and Auto PCI...

Страница 119: ...Offboard Onboard LAN Option ROM Type Use this item to select the device type for onboard LAN Option ROM for system boot The options are EFI and Legacy Onboard LAN 1 OpROM Onboard LAN 2 OpROM Select iS...

Страница 120: ...bled and Disabled TPM Trusted Platform Module State Select Enabled to enable TPM security settings to improve data integrity and network security The options are Disabled and Enabled Pending Operation...

Страница 121: ...p used in the motherboard Serial Port 1 Configuration Serial Port Select Enabled to enable a serial port specified by the user The options are Enabled and Disabled Device Settings This item displays t...

Страница 122: ...eature to select the attribute for this serial port The options are SOL Serial Over LAN and COM Serial Port Console Redirection COM 1 COM 1 Console Redirection Select Enabled to enable COM Port 1 Cons...

Страница 123: ...along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial dat...

Страница 124: ...ole Redirection remains enabled upon OS bootup The options are Always Enable and Bootloader SOL COM2 Console Redirection Select Enabled to use the SOL port for Console Redirection The options are Enab...

Страница 125: ...along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial dat...

Страница 126: ...on Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 7 4 Event Logs Select the Event Logs tab to access...

Страница 127: ...abled Erasing Settings Erase Event Log Select Enabled to erase the SMBIOS System Management BIOS event log which is completed before a event logging is initialized upon system reboot The options are N...

Страница 128: ...M s EFI Status codes that is not in Legacy format The options are Enabled and Disabled Convert OEM Codes Select Enabled to convert the OEM s EFI Status codes to standard SMBIOS compatible codes The op...

Страница 129: ...the following submenu items These items indicates your system IPMI firmware revision number and status IPMI Firmware Revision IPMI Status System Event Log Enabling Disabling Options SEL Components Sel...

Страница 130: ...ate IPMI LAN Configuration Select Yes for the system BIOS to automatically reset the following IPMI settings at next system boot The options are Yes and No Configuration Address Source Available when...

Страница 131: ...and in dotted quad form i e 192 168 10 253 When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration...

Страница 132: ...this item to set the administrator password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this item t...

Страница 133: ...ions are Legacy UEFI and Dual Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devi...

Страница 134: ...iority list Delete Driver Option Select the target driver to delete Network Drive BBS Priorities Available when a device is installed in this drive This item sets the boot sequence of available networ...

Страница 135: ...ave the changes and exit from the BIOS setup utility Discard Changes and Exit Select this option to quit the BIOS setup without making any changes to the system configuration Select Discard Changes an...

Страница 136: ...r to load the optimized default settings that help optimize system performance When the dialog box appears asking you if you want to load the factory defaults select Yes to load the optimized default...

Страница 137: ...rs are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error A 1 BIOS Error Beep Codes Motherboard BI...

Страница 138: ...A 2 SUPERSERVER 8028B TR3F C0R3FT User s Manual Notes...

Страница 139: ...memory sizes of 4GB 8GB 16GB 32GB and 64GB size 1 35V 1 5V voltages SAS SATA Controller Intel C602J on chip controller for six port SATA subsystem two SATA 3 0 and four SATA 2 0 ports which is RAID 0...

Страница 140: ...ng fans are NOT redundant hot plug System Input Requirements AC Input Voltage 90 240V AC auto range Rated Input Current 15A max full load Rated Input Frequency 50 to 60 Hz AC Platinum 80 Platinum Leve...

Страница 141: ...1000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations...

Страница 142: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell suc...

Отзывы: