41
Chapter 3: Maintenance and Component Installation
6019P-MTR
The 6019P-MTR has a redundant 600W power supply, consisting of two power supply
modules. These power supplied are auto-switching capable, which enables it to automatically
sense and operate with a 100V to 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load and allow
the system to continue operation without interruption. The Power Fail LED will illuminate and
remain on until the failed unit has been replaced. Replacement units can be ordered directly
from Supermicro (see contact information in the Preface).
The hot-swap capability of the power supply modules allows you to replace the failed module
without powering down the system..
Replacing the Power Supply
1. Check the LEDs on the power supplies to determine which module has failed.
2. Unplug the power cord from the failed module.
3. Push the release tab (on the back of the power supply) as illustrated, then pull the
power supply out using the handle provided.
4. Push the new power supply module into the power bay until you hear a click (replace
with the same model: p/n PWS-608P-1R).
5. Reconnect the power cord to the new module.