ERVER 6015V-M3/6015V-MT User's Manual
5-2 Serverboard
Installation
This section explains the fi rst step of physically mounting the X7DVL-3/X7DVL-i into
the SC813MTQ-520C chassis. Following the steps in the order given will eliminate
the most common problems encountered in such an installation. To remove the
serverboard, follow the procedure in reverse order.
1.
Accessing the inside of the system (see Figure 2-5)
Two release buttons are located on the top cover of the chassis. Depressing
both of these buttons while pushing the cover away from you until it stops. You
can then lift the top cover from the chassis to gain full access to the inside of
the server. (If already installed in a rack, you must fi rst release the retention
screws that secure the unit to the rack. Then grasp the two handles on either
side and pull the unit straight out until the rails lock into place.)
2. Check compatibility of serverboard ports and I/O shield
The X7DVL-3/X7DVL-i requires a chassis big enough to support a 12" x 10"
serverboard, such as Supermicro's SC813MTQ-520C 1U rackmount. Make
sure that the I/O ports on the serverboard align properly with their respective
holes in the I/O shield at the back of the chassis.
3. Mounting the serverboard onto the serverboard tray
Carefully mount the serverboard to the serverboard tray by aligning the board
holes with the raised metal standoffs that are visible in the chassis. Insert
screws into all the mounting holes on your serverboard that line up with the
standoffs and tighten until snug (if you screw them in too tight, you might strip
the threads). Metal screws provide an electrical contact to the serverboard
ground to provide a continuous ground for the system.
Unpacking
The serverboard is shipped in antistatic packaging to avoid electrical static dis-
charge. When unpacking the board, make sure the person handling it is static
protected.
Содержание SUPERSERVER 6015V-M3
Страница 1: ...SUPER SUPERSERVER 6015V M3 SUPERSERVER 6015V MT USER S MANUAL Revision 1 0b...
Страница 5: ...v Preface Notes...
Страница 10: ...x Notes SUPERSERVER 6015V M3 6015V MT User s Manual...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the SuperServer 6015V M3 6015V MT...
Страница 30: ...3 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Страница 66: ...6 8 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Страница 98: ...A 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Страница 104: ...B 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Страница 118: ...D 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...