Chapter 2: Server Installation
2-7
Figure 2-3. Installing the Server into a Telco Rack
(with optional front bezel shown)
Installing the Server into a Telco Rack
To install the SuperServer 6015V-M3/6015V-MT into a Telco type rack, use two
L-shaped brackets on either side of the chassis (four total). First, determine how
far the server will extend out the front of the rack. Larger chassis should be posi-
tioned to balance the weight between front and back. If a bezel is included on your
server, remove it. Then attach the two front brackets to each side of the chassis,
then the two rear brackets positioned with just enough space to accommodate the
width of the rack. Finish by sliding the chassis into the rack and tightening the
brackets to the rack.