Chapter 6: Optional Components
11. If cross-controller RAID is required, select
Enable RAID spanned over VMD Controller
as shown in the figures below.
Figure 6-1. Created Volume
without
enabling RAID spanned over VMD
controller
Figure 6-2. Created Volume
with
enabling RAID spanned over VMD
controller
12.
Select specific disks for RAID with an [X].
•
RAID0: Select at least two [2 - 24] disks
•
RAID1: Select only two disks
•
RAID5: Select at least three [3 - 24] disks
•
RAID10: Select only four disks
13. Select
Strip Size
(Default 64KB).
14. Select
Create Volume
.
15. If another RAID is needed, start again at step 6.