![Supermicro SuperServer 510P-M Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/supermicro/superserver-510p-m/superserver-510p-m_user-manual_1404606076.webp)
76
Chapter 6: Optional Components
6.3 3.5" to 2.5" Drive Trays
•
Tool-less black hot-swap 3.5" to 2.5" Gen 5.5 drive tray (MCP-220-00138-0B, orange tab,
w/ key lock, clip design)
•
Black hot-swap 3.5" to 2.5" Gen 4 drive tray (MCP-220-00043-0N)
Enabling NVMe RAID
RAID for NVMe SSDs must be enabled through the UEFI BIOS.
1. Install the patch as described in the Restrictions and Requirements section on a
previous page.
2. Reboot the server.
3. Press [DEL] key to enter BIOS.
4. Switch to
Advanced > Chipset Configuration > North Bridge > IIO Configuration >
Intel® VMD Technology
.
5.
Enable
the VMD according to the following rules.
•
For M.2 NVMe or NVMe AIC, enable the VMD according to which AOC card/slot it used.
Examples for some U.2 configurations follow.
6.
Press [F4] to save the configuration and reboot the system.
7. Press [DEL] to enter BIOS.
8. Switch to
Advanced > Intel(R) Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume
.
9. Set
Name
.
10. Set
RAID Level
.