Chapter 2: Server Installation
24
Figure 2-2. Installing the Server into a Telco Rack
Note:
Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.
Installing the Server into a Telco Rack
To install the 510P-M/MR into a Telco type rack, use two L-shaped brackets on either side
of the chassis (four total).
1. First, determine how far the server will extend out the front of the rack. Larger chassis
should be positioned to balance the weight between front and back. If a bezel is
included on your server, remove it.
2. Then attach the two front brackets to each side of the chassis, then the two rear
brackets positioned with just enough space to accommodate the width of the rack.
3. Finish by sliding the chassis into the rack and tightening the brackets to the rack.