background image

USER’S MANUAL 

Revision 1.0a

SuperServer

®

5029C-T

Содержание SuperServer 5029C-T

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 5029C T...

Страница 2: ...nvironment or residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may c...

Страница 3: ...ers and utilities https www supermicro com wftp driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at su...

Страница 4: ...allation 2 1 Removing Power 17 2 2 Hardware Security 17 Front Bezel Lock 17 Rear Chassis Hasp 18 Kensington Cable Slot K Slot 18 2 3 Accessing the System 19 2 4 Motherboard Components 20 Processor 20...

Страница 5: ...45 3 4 Jumpers 48 Explanation of Jumpers 48 3 5 LED Indicators 50 Chapter 4 Software 4 1 Microsoft Windows OS Installation 52 4 2 Driver Installation 54 4 3 SuperDoctor 5 55 4 4 IPMI 56 Chapter 5 BIOS...

Страница 6: ...rope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermic...

Страница 7: ...02 0N 1 Optional 2 5 to 3 5 SSD HDD adapter tray MCP 220 00043 0N Chapter 1 Introduction 1 1 Overview The SuperServer 5029C T is a compact server system comprised of the SC721TQ 250B2 chassis and the...

Страница 8: ...850 RPM Memory Two 2 DDR4 2666MHz ECC UDIMM slots max capacity 64GB Expansion Slots One 1 PCI E3 0 x16 for low profile AOC Hard Drives Four 4 hot swap 3 5 SAS2 SATA3 drive bays with Backplane SES II T...

Страница 9: ...hassis Front View 1 3 Chassis Features Front Features The SC721TQ 250B2 is a compact Mini Tower chassis The front of the chassis includes a power on off push button a reset button and several LEDs as...

Страница 10: ...flashing 7 Information LED This LED alerts the operator to several states as noted in the table below 8 Front Bezel Lock Data security and protection by a key 9 Hot swappable Drives Support four 3 5...

Страница 11: ...r Chassis Features Item Feature Description 1 Power Supply Fixed module 2 I O Backpanel Rear input output ports 3 PCI E Slots Supports four full height full length PCI E expansion cards 4 Kensington S...

Страница 12: ...l Rear I O Ports Figure 1 3 Rear input Output Ports Rear I O Ports Description Description 1 COM1 6 USB4 USB 3 1 Gen 1 2 Dedicated IPMI LAN 7 LAN2 3 USB1 8 LAN1 4 USB0 9 VGA Port 5 USB5 USB 3 1 Gen 1...

Страница 13: ...ents X11SCL IF REV 1 01 1 BIOS LICENSE BAR CODE DESIGNED IN USA Intel i210 Intel C242 ASpeed AST2500 JPL1 FANA JLED1 JPME2 JWD1 JPL2 JPG1 JSTBY1 USB2 3 CPU SLOT1 PCI E 3 0 X16 B1 JL1 LED4 M 2 H MH5 LE...

Страница 14: ...ort FAN1 FAN3 FANA CPU System Fan Headers IPMI_LAN Dedicated IPMI LAN Port I SATA0 I SATA3 Intel PCH SATA 3 0 Ports with RAID 0 1 5 10 I SATA2 and I SATA3 supports SuperDOM I SGPIO1 Serial Link Genera...

Страница 15: ...ion SP1 Onboard Buzzer USB0 1 Back Panel Universal Serial Bus USB 2 0 Ports USB2 3 Front Accessible USB 2 0 Header USB4 5 Back Panel USB 3 1 Gen 1 Ports USB6 7 Front Accessible USB 3 1 Gen 1 Header US...

Страница 16: ...DDR4 CHA DIMMA1 DDR4 CHB 65W 71 W 80W 95W PCIe x16 SLOT 6 DIMMB1 RJ45 GLAN2 I210 AT RJ45 GLAN1 I210 AT PCIEX4 M 2 M KEY REAR USB USB Header VGA 32MB PCH_SPI PCH CPU BMC RMII NCSI MUX LANUSB2 0 x4 DMI...

Страница 17: ...stem This step is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system ha...

Страница 18: ...a variety of commonly available locks not included Figure 2 1 Front Bezel Lock Figure 2 2 Rear Chassis Hasp Figure 2 3 Inserting a Kensington Cable Device not included Kensington Cable Slot K Slot Th...

Страница 19: ...down the system as described in section 2 1 2 Lift the release lever located on the right side rear of the chassis 3 Slide the cover toward the rear of the chassis the lift it off Caution Except for...

Страница 20: ...iving a motherboard without a processor pre installed make sure that the plastic protective socket cover is in place and none of the socket pins are bent otherwise contact your retailer immediately In...

Страница 21: ...semi circle cutouts may also be aligned against the socket keys as a guide 4 Carefully lower the CPU straight down into the socket Do not drop the CPU on the socket or move it horizontally or vertica...

Страница 22: ...hassis cover 2 Remove the three screws securing the rear tray to the rear of the chassis and set them aside for later use 3 Pull the rear tray out from the chassis see Figure 2 7 4 Place the heatsink...

Страница 23: ...nside of the chassis Hook Hook Figure 2 6 Positioning the Air Shroud 2 Clip both hooks on the top of the air shroud onto the top fin of the heatsink properly 3 Peel off two pieces of double sided tape...

Страница 24: ...24 SuperServer 5029C T User s Manual 4 Push the rear tray back into the the chassis Figure 2 8 Pushing the Rear Tray Back Into the Chassis...

Страница 25: ...e power from the system as described in Section 3 1 2 Remove the air shroud from the heatsink Note that the taped surface of both sides of the air shroud will retain their adhesive so that you can re...

Страница 26: ...moving DIMM modules to prevent damage Memory Population Guidelines Refer to the tables below for the recommended DIMM population order and additional memory information 1 CPU 2 DIMM Slots Number of DI...

Страница 27: ...lot to unlock it 3 Align the key of the DIMM module with the receptive point on the memory slot 4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Pr...

Страница 28: ...is tray that holds the motherboard and rear I O shield Installing an Expansion Card 1 Power down the system as described in Section 2 1 and remove the chassis cover 2 Remove the three screws securing...

Страница 29: ...t aside for later use 5 Slide the PCI slot shield up and out of the PCI slot 6 Insert the card into its slot on the motherboard while aligning its bracket into the slot on the chassis drawer 7 Secure...

Страница 30: ...To insert a new battery slide one edge under the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do...

Страница 31: ...htening all six screws The logic and power connections to the drive will be supplied through the backplane 2 5 Chassis Components Front Mounted Hot Swap Drives The SC721TQ 250B2 supports four hot swap...

Страница 32: ...Cage Hard Drive Carrier Dummy Drive Hard Drive Installing a Drive Carrier into the Hard Drive Cage 1 Insert the hard drive carrier into the drive bay using the drive carrier handle to push it all the...

Страница 33: ...as described in Section 2 1 and remove the chassis cover 2 Place a 2 5 hard drive into the hard drive bracket and secure the drive to the bracket with the four screws provided 3 Place the hard drive...

Страница 34: ...rd drive bracket and secure the hard drive to the bracket with the four screws provided 3 Place the hard drive and bracket into the side mounting position of the chassis by inserting the pin on the br...

Страница 35: ...110 There is a standoff for each length 1 Remove power from the system as described in section 2 1 and remove the chassis cover 2 Find and pull out the plastic securing knob in one of the M 2 standoff...

Страница 36: ...Module Note You might experience temporary M 2 speed throttling when it reaches its thermal threshold which depends on the specifications of your device Please note that this is a normal phenomenon an...

Страница 37: ...the chassis cover as described in Section 2 3 2 Unlock the front bezel and swing it open 3 Remove the bracket for the top mounted fixed hard drive by removing the two screws 4 Remove the two screws se...

Страница 38: ...nstalling a DVD Drive Figure 2 21 Securing the Bracket Rail to a DVD Drive 7 Bracket Rail 8 Slide the DVD drive into the chassis until it snaps into place Some DVD drives allow you to secure the drive...

Страница 39: ...down the system as described in Section 2 1 and remove the chassis cover as described in Section 2 3 2 Place the fan on top of the fan grill aligning the mounting holes of the fan grill with the moun...

Страница 40: ...ll power cables from the motherboard hard drives and backplane 3 Remove the screws securing the power supply to the chassis which are located on the rear of the chassis Set these screws aside for late...

Страница 41: ...Power Connections ATX Power Supply Connector The primary 24 pin power supply connector JPW1 meets the ATX SSI EPS 12V specification A 4 pin JPW2 processor power connector must also be connected to yo...

Страница 42: ...on Pin Definition 1 3 3V 2 SPI_CS 3 RESET 4 SPI_MISO 5 SPI_CLK 6 GND 7 SPI_MOSI 8 NC 9 3 3V Stdby 10 SPI_IRQ TPM Port 80 Header A Trusted Platform Module TPM Port 80 header is located at JTPM1 to prov...

Страница 43: ...e Serial Link General Purpose Input Output I SGPIO1 header located on the motherboard The SGPIO header is used to communicate with the enclosure management chip on the back panel Disk On Module Power...

Страница 44: ...d buzzer at SP1 To use an extra speaker instead connect the speaker connector to pins 1 4 Refer to the table below for pin definitions Speaker Onboard Buzzer Header Pin Definitions Pin Signal 1 P5V 2...

Страница 45: ...on the back I O panel Use this connection for VGA display COM Port There is one COM port COM1 on the back I O panel on the motherboard The COM port provides serial communication support COM Port Pin D...

Страница 46: ...A5 Stda_SSRX B5 USB3_RN A6 Stda_SSRX B6 USB3_RP A7 GND B7 GND A8 Stda_SSTX B8 USB3_TN A9 Stda_SSTX B9 USB3_TP Back Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 U...

Страница 47: ...13 TD1 23 SGND 14 TD2 24 SGND 15 TD2 25 SGND 16 TD3 26 SGND 17 TD3 18 GND Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and an LED indicator are located on the motherboard The...

Страница 48: ...en completely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to preven...

Страница 49: ...lication hangs Close pins 2 3 to generate a non maskable interrupt NMI signal for the application that hangs Refer to the table below for jumper settings The Watchdog must also be enabled in the BIOS...

Страница 50: ...olor Status Definition Green Flashing Active LAN Link LED Left LED State LED Color Definition Off No Connection 10 Mbps Amber 1 Gbps Green 100 Mbps IPMI LAN LEDs In addition to LAN1 2 an IPMI LAN is a...

Страница 51: ...to turn off the system and unplug the power cord before removing or installing components Refer to the table below for more information Onboard Power LED Indicator LED Color Definition Off System Off...

Страница 52: ...iguration User Guides posted on our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using a...

Страница 53: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 54: ...f preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the fl...

Страница 55: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 56: ...access monitoring and management There are several BIOS settings that are related to IPMI Supermicro ships standard products with a unique password for the BMC ADMIN user This password can be found on...

Страница 57: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be co...

Страница 58: ...ht System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time...

Страница 59: ...Chapter 5 BIOS 59 CPLD Version This item displays the Complex Programmable Logic Device version Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 60: ...le this feature to reduce the time the computer takes to boot up The computer will boot with a minimal set of required devices This feature does not have an effect on BBS boot options in the Boot tab...

Страница 61: ...to set the power state after a power outage Select Stay Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last S...

Страница 62: ...atio Override is enabled this feature sets the value for the CPU Flex Ratio This value must be between the maximum efficiency ratio and maximum non turbo ratio The default value is dependent on the CP...

Страница 63: ...at system reset or reboot The options are Disabled and Enabled AES Select Enabled to use the Intel Advanced Encryption Standard AES to ensure data security The options are Disabled and Enabled Boot P...

Страница 64: ...er saving feature for the CPU C1E drops the frequency and voltage of the CPU to reduce power usage when the system is idle The options are Disabled and Enabled C State Auto Demotion Use this feature t...

Страница 65: ...modules The options are Auto 1067 1333 1400 1600 1800 1867 2000 2133 2200 2400 2600 and 2667 ECC Support Use this feature to enable Error Checking Correction ECC support for onboard memory modules Th...

Страница 66: ...DMI Extended Sync Control Use this feature to enable or disable the DMI extended synchronization The options are Enabled and Disabled DMI De Emphasis Control Use this feature to configure the De emph...

Страница 67: ...rogrammed before OPROM The options are Disabled and Enabled VT d Select Enable to use Intel Virtualization Technology for Direct I O VT d support by reporting the I O device assignments to the VMM Vir...

Страница 68: ...rols the Active State Power Management ASPM setting The op tions are Disabled L0s L1 L0sL1 and Auto M 2 H L1 Substates Use this feature to configure the PCI Express L1 Substates The options are Dis ab...

Страница 69: ...to allow the BIOS to automatically assign the base I O and IRQ address The options for Serial Port 1 are Auto IO 3F8h IRQ 4 IO 2F8h IRQ 4 IO 3E8h IRQ 4 and IO 2E8h IRQ 4 SOL Configuration This submen...

Страница 70: ...nsmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and...

Страница 71: ...ns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects the settings for Function Keys and KeyPad used for Putty which is a terminal emul...

Страница 72: ...number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transm...

Страница 73: ...s are Always Enable and BootLoader Legacy Console Redirection Legacy Console Redirection Settings Legacy Redirection COM Port Use this feature to select a COM port to display redirection of Legacy OS...

Страница 74: ...nd This feature sets the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed...

Страница 75: ...r system boot Select Legacy to load a legacy driver for system boot The options are Do Not Launch UEFI and Legacy Serial ATA Port 0 Port 3 This feature displays the information detected on the install...

Страница 76: ...gh Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing th...

Страница 77: ...lect Enabled for USB mass storage device support The options are Disabled and Enabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which will provide complete USB keyboar...

Страница 78: ...loaded for the add on card in this slot The options are Disabled Legacy and EFI Onboard LAN Option ROM Type Use this feature to select which firmware type to be loaded for onboard LAN ports The optio...

Страница 79: ...a Detect Count Use this feature to specify the number of times media will be checked Press or on your keyboard to change the value The default setting is 1 Trusted Computing The X11SCL IF supports TPM...

Страница 80: ...Hierarchy Use this feature to disable or enable storage hieararchy for cryptographic protection The options are Disabled and Enabled Endorsement Hierarchy Use this feature to disable or enable endorse...

Страница 81: ...eature to have the system auto boot into the newly created HTTP boot option the next time the system is powered on The options are Disabled and Enabled Input The Description Use this feature to input...

Страница 82: ...tion Enroll Certification Using File Use this feature to enroll certification from a file Certification GUID Use this feature to input the certification GUID Commit Changes and Exit Use this feature t...

Страница 83: ...g Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next reset data in the event log will be erased upon next system reboot Select Yes Every reset d...

Страница 84: ...ounter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is i...

Страница 85: ...ware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Era...

Страница 86: ...MI LAN setting The default setting is Failover IPMI Network Link Status This feature displays the IPMI Network Link status The default setting is Shared LAN Configuration Address Source This feature a...

Страница 87: ...e displays the IPV6 Address status The default setting is Disabled IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled If the feature above is set to Enabled the...

Страница 88: ...g the BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator password Secure Boot This section displays the contents...

Страница 89: ...Yes and No Export Secure Boot variables Use this feature to copy the NVRAM contents of the secure boot variables to a file Enroll EFI Image This feature allows the image to run in Secure Boot Mode Enr...

Страница 90: ...base from the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Update Select Yes to load the DBX from the manufacturer s...

Страница 91: ...FI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Update Select Yes to load the DBR from the manufacturer s default...

Страница 92: ...Boot Mode Select Use this feature to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual Fixed Boot Order Priorities This feature prioritizes the order...

Страница 93: ...to select an EFI boot option to delete from the boot order Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list Delete Driver Option This feature allows the us...

Страница 94: ...ture to specify the name for the new driver option Path for Boot Option Use this feature to enter the path for the new driver option in the format fsx path filename efi Driver Option File Path Use thi...

Страница 95: ...5 UEFI Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devices Boot Option 1 Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devic...

Страница 96: ...d press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you...

Страница 97: ...Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from...

Страница 98: ...o com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnos...

Страница 99: ...r assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...

Страница 100: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 101: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...

Страница 102: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 103: ...s del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l instal...

Страница 104: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 105: ...els aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warn...

Страница 106: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 107: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s u...

Страница 108: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 109: ...nbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All conn...

Страница 110: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 111: ...ertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques cir...

Страница 112: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 113: ...e elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordin...

Страница 114: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 115: ...tornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient tou...

Страница 116: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 117: ...e code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto util...

Страница 118: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 119: ...rive bays with Backplane SES II Two 2 internal fixed 2 5 drive bays One 1 M 2 slot through PCI E3 0 x4 SATA3 0 Supports M key 2280 Expansion Slots One 1 PCI E3 0 x16 for low profile AOC Motherboard X1...

Страница 120: ...1 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlora...

Страница 121: ...sence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the...

Страница 122: ...122 Appendix D BSMI RoHS 100 240V 60 50Hz 4 2A 150 3...