B-2
S
UPER
S
ERVER 1028UX-TR4 User's Manual
System Cooling
Four sets of 4-cm counter-rotating cooling fans (fan speed controlled by IPMI)
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 9.5-4.5 Amps
Rated Input Frequency: 50-60 Hz
Power Supply
80-plus Platinum AC-DC, (Part# PWS-750P-1R)
Rated Output Power: 750W
Rated Output Voltages: +12V, +12Vsb (2A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-Operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-Operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See
www.dtsc.ca.gov/hazardouswaste/perchlorate
”
Содержание SUPERSERVER 1028UX-TR4
Страница 1: ...User s Manual Revision 1 0a SUPERSERVER 1028UX TR4...
Страница 5: ...v SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 14: ...1 6 SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 24: ...2 10 SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 72: ...5 24 SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 84: ...6 12 SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 126: ...A 2 SUPERSERVER 1028UX TR4 User s Manual Notes...
Страница 130: ...B 4 SUPERSERVER 1028UX TR4 User s Manual Notes...